Fabrication and optimization of a multielectrode microfluidic electrochemical flow cell for fast and dynamic detection of reaction products
Bibliographic record
Abstract
Construction and experimental validation of electrochemical cells with multiple electrodes in a microfluidic channel is described. Details of the fabrication of the electrodes and polydimethylsiloxane channel using soft lithography methods are given. Calibration of the collection efficiencies and transit times between electrodes validate the use of these cells for fast electrochemical detection of soluble species. Mass transit times between two electrodes down to 3 ms with a flow rate of 200 µL min -1 are demonstrated. We demonstrate that there is an upper limit in the electrode width to channel height ratio depending on the electrolyte conductivity. A recommendation for the maximum electrode width to channel height ratio is presented. The electrode width is recommended to not exceed four times the height of the channel in 0.1 M H 2 SO 4 . We also demonstrate operating strategies to minimize the impact of oxygen in air, optimization of stepping motor syringe pump parameters, electrolyte switching, and show how to deposit catalyst particles on a channel electrode. • Fabrication methods are given for all components of microfluidic flow cells with multiple electrodes • Conditions are given for improved operation, including geometry, pumping, and electrical parameters.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".