MétaCan
Menu
Back to cohort

Susceptibility Assessment of Oscillometry Parameters to Motion Artifact

2024· article· en· W4405489448 on OpenAlexafffund
Seyedfakhreddin Nabavi, Lennart K. A. Lundblad, Bryan Ross

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicNon-Invasive Vital Sign Monitoring
Canadian institutionsMcGill UniversityChristie (Canada)McGill University Health Centre
FundersMcGill University Health Centre
KeywordsArtifact (error)Computer scienceMotion (physics)Artificial intelligence

Abstract

fetched live from OpenAlex

In recent years, the use of remote patient monitoring technologies has extended the diagnosis and surveillance of chronic diseases beyond hospitals. In chronic respiratory diseases, oscillometry measurement has been recognized as a portable approach that can be used in non-laboratory, unsupervised environments to measure lung function serially. In this study, the susceptibility of oscillometry output signals to motion artifact is investigated. Through a comprehensive experimental measurement, it is found that the coefficient of variation of the oscillometer output signals increases 4.51 times in the presence of motion artifact. The maximum deviation in the oscillometer signals caused by motion artifact was observed in the reactance parameter at a low frequency of 5 Hz. Results indicate that a signal processing technique to address motion artifacts can enhance the quality of data obtained from unsupervised oscillometry testing. This will help further establish oscillometry as an accurate and reliable remote outpatient lung function monitoring modality.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.187
Threshold uncertainty score0.401

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.284
Teacher spread0.265 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes2
Has abstractyes

Explore more

Same topicNon-Invasive Vital Sign MonitoringFrench-language works237,207