MétaCan
Menu
Back to cohort
Record W4405557356 · doi:10.18240/ijo.2025.01.09

Outcomes of a non-diffractive extended depth of focus intraocular lens in patients with well-controlled glaucoma and ocular hypertension

2024· article· en· W4405557356 on OpenAlexaffabout
Jiaru Liu, Paul Harasymowycz

Bibliographic record

VenueInternational Journal of Ophthalmology · 2024
Typearticle
Languageen
FieldMedicine
TopicOphthalmology and Visual Impairment Studies
Canadian institutionsBell (Canada)Hôpital du Sacré-Cœur de MontréalHôpital Maisonneuve-RosemontUniversité de Montréal
Fundersnot available
KeywordsMedicineOphthalmologyGlaucomaOcular hypertensionOptometryFocus (optics)Depth of focus (tectonics)Lens (geology)Optics

Abstract

fetched live from OpenAlex

AIM: To assess visual outcomes and satisfaction of a non-diffractive extended depth of focus (EDOF) intraocular lens (IOL) in individuals with ocular hypertension (OHT) and well-controlled mild glaucoma undergoing cataract surgery. METHODS: An investigator-initiated, single-center, prospective, interventional, noncomparative study conducted in Montreal, Canada. The study enrolled 31 patients (55 eyes) with OHT or mild glaucoma who received a non-diffractive EDOF IOL (Acrysof IQ Vivity). Participants underwent sequential cataract surgery with the Vivity IOL. Follow-up evaluations occurred at 1d, 1, and 3mo postoperatively, assessing uncorrected distance, intermediate, and near visual acuity. Questionnaires (QUVID: Questionnaire for visual disturbances and IOLSAT: Intraocular lens satisfaction) were administered pre and post-operatively to measure visual disturbances and spectacle independence in various lighting. Safety parameters included intraocular pressure (IOP), glaucoma medications, spherical equivalence, mean deviation and pattern standard deviation or square root of lost variance on Octopus visual field. RESULTS: At 1 and 3mo postoperatively, significant improvements were observed in uncorrected distance and intermediate visual acuity. Spectacle independence was enhanced for distance and intermediate vision, especially in bright light settings. Spectacle-free intermediate vision was improved even in dim lighting. Visual disturbances, particularly glare symptoms, were reduced, and there was a notable decrease in IOP and glaucoma medication burden at 3mo. There was more hazy vision postoperatively with no impact on visual acuity and visual satisfaction. CONCLUSION: The non-diffractive EDOF lens improves distance and intermediate spectacle-free visual function in patients with OHT and well-controlled glaucoma. The findings highlight significant improvements in visual acuity, reduced glare, enhanced spectacle independence, and improved visual performance in different lighting conditions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.009
Threshold uncertainty score0.429

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.323
Teacher spread0.308 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2024
Admission routes2
Has abstractyes

Explore more

Same venueInternational Journal of OphthalmologySame topicOphthalmology and Visual Impairment StudiesFrench-language works237,207