MétaCan
Menu
Back to cohort
Record W4405667147 · doi:10.1016/j.measen.2024.101423

Development and calibration of a measurement system for the characterization of avalanche photodiodes prospectively used as sensors in X-ray Compton polarimeters for space

2024· article· en· W4405667147 on OpenAlexfundno aff
Andrea Alimenti, Fabrizio Cologgi, Enrico Silva, Sergio Fabiani, A. Rubini, Pasqualino Loffredo, Giovanni Lombardi, P. Soffitta, E. Del Monte, E. Costa, Nicolas De Angelis, Sergio Di Cosimo, Fabio Muleri, Alessandro Di Marco, Anthony C. Terracciano, Emanuele Zaccagnino, I. Donnarumma, Daniele Brienza, Giuseppe Leccese, A. Fedele, Silvia Natalucci, G. Cucinella, Andrea Negri, Sergio Bonomo, Simone Di Filippo, Massimo Perelli, Dario Modenini, Andrea Curatolo, Alfredo Locarini, Paolo Tortora, Ilaria Baffo, Pierluigi Fanelli, A. Del Re, Giulia De Iulis, Paolo Leonetti, Alessandro Zambardi, G. De Cesare, R. Campana, Mauro Centrone, G. Minervini

Bibliographic record

VenueMeasurement Sensors · 2024
Typearticle
Languageen
FieldPhysics and Astronomy
TopicRadiation Detection and Scintillator Technologies
Canadian institutionsnot available
FundersInstitut sur la Nutrition et les Aliments Fonctionnels
KeywordsAvalanche photodiodeCalibrationX-rayCharacterization (materials science)PhotodiodePhysicsOpticsSpace (punctuation)Materials scienceOptoelectronicsDetectorComputer science

Abstract

fetched live from OpenAlex

Solar flares, dynamic eruptions of electromagnetic radiation from the Sun's surface, represent a potential risk for various human technological infrastructures. The CUbesat Solar Polarimeter (CUSP) project, part of the Alcor Program of the Italian Space Agency, aims to measure solar flare polarization in the hard X-ray band. This paper focuses on the design and setup of a measurement system to characterize the response of the avalanche photodiodes (APD) used in the CUSP polarimeter. The system is tested at room temperature conditions by varying both incident photon energy between 20 keV and 135 keV, using X-ray sources as references, and APD bias voltage from 260 V to 410 V. Using the calibrated system, the dependence of APD gain on bias voltage, and its energy resolution, are measured, matching the metrological standards of the polarimeter.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.040
GPT teacher head0.242
Teacher spread0.202 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2024
Admission routes1
Has abstractyes

Explore more

Same venueMeasurement SensorsSame topicRadiation Detection and Scintillator TechnologiesFrench-language works237,207