MétaCan
Menu
Back to cohort
Record W4406216502 · doi:10.3390/atoms13010006

Exploring the Nuclear Chart via Precision Mass Spectrometry with the TITAN MR-TOF MS

2025· article· en· W4406216502 on OpenAlexafffund
Annabelle Czihaly, Sönke Beck, J. Bergmann, Callum L. Brown, T. Brunner, T. Dickel, J. Dilling, E. Dunling, Jake Flowerdew, D. Fusco, Leigh Graham, Zach Hockenbery, C. Izzo, Andrew Jacobs, B. Kootte, S. Malbrunot-Ettenauer, Fernando Maldonado Millán, Ali Mollaebrahimi, E. Leistenschneider, E. M. Lykiardopoulou, Ish Mukul, S. F. Paul, W. R. Plaß, M. P. Reiter, C. Scheidenberger, J. L. Tracy, A. A. Kwiatkowski

Bibliographic record

VenueAtoms · 2025
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAstronomical and nuclear sciences
Canadian institutionsUniversity of ManitobaUniversity of British ColumbiaMcGill UniversityUniversity of CalgaryUniversity of VictoriaUniversity of WaterlooTRIUMF
FundersNatural Sciences and Engineering Research Council of CanadaJustus Liebig Universität GießenHelmholtz Graduate School for Hadron and Ion ResearchDeutsche ForschungsgemeinschaftTRIUMFBundesministerium für Bildung und Forschung
KeywordsNuclidePhysicsNuclear astrophysicsIsotopeTitan (rocket family)Mass spectrometryNuclear physicsNuclear engineeringAstrobiology

Abstract

fetched live from OpenAlex

Isotopes at the limits of nuclear existence are of great interest for their critical role in nuclear astrophysical reactions and their exotic structure. Experimentally, exotic nuclides are challenging to address due to their low production cross-sections, overwhelming amounts of contamination, and lifetimes of typically less than a second. To this end, a Multiple-Reflection Time-of-Flight mass spectrometer at the TITAN-TRIUMF facility was built to determine atomic masses. This device is the preferred tool to work with exotic nuclides due to its ability to resolve the species of interest from contamination and short measurement cycle times, enabling mass measurements of isotopes with millisecond half-lives. With a relative precision of the order 10−7, we demonstrate why the TITAN MR-TOF MS is the tool of choice for precision mass surveys for nuclear structure and astrophysics. The capabilities of the device are showcased in this work, including new mass measurements of short-lived tin isotopes (104–107Sn) approaching the proton dripline as well as 89Zr, 90Y, and 91Y. The last three illustrate how the broadband surveys of MR-TOF MS reach beyond the species of immediate interest.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.211
Teacher spread0.197 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueAtomsSame topicAstronomical and nuclear sciencesFrench-language works237,207