MétaCan
Menu
Back to cohort
Record W4406320372 · doi:10.1016/j.jcv.2025.105762

Evaluation of a next generation sequencing assay for Hepatitis B antiviral drug resistance on the oxford nanopore system

2025· article· en· W4406320372 on OpenAlexaff
Michael Payne, Gordon Ritchie, Tanya Lawson, Matthew Young, Willson Jang, Aleksandra Stefanovic, Marc G. Romney, Nancy Matic, Christopher F. Lowe

Bibliographic record

VenueJournal of Clinical Virology · 2025
Typearticle
Languageen
FieldMedicine
TopicHepatitis B Virus Studies
Canadian institutionsSt. Paul's HospitalProvidence Health Care
Fundersnot available
KeywordsNanopore sequencingVirologyDrug resistanceComputational biologyDNA sequencingDrugMedicineBiologyGeneticsPharmacologyGene

Abstract

fetched live from OpenAlex

• Next-generation sequencing on the Miseq and Oxford nanopore system were comparable for the detection of HBV genotype and antiviral resistance (AVR) mutations. • Oxford nanopore System, with updated R10.4.1 flowcells, provides accurate AVR mutation identification with <1 % sequence error rates. • Oxford nanopore system demonstrated improved testing turn-around time for clinical sequencing results. Next-generation sequencing (NGS) for Hepatitis B virus (HBV) antiviral resistance (AVR) testing is a highly sensitive diagnostic method, able to detect low-level mutant subpopulations. Our clinical virology laboratory previously transitioned from DNA hybridization (INNO-LiPA) to NGS, initially with the GS Junior System and subsequently the MiSeq. The Oxford Nanopore Technology (ONT) sequencing system was evaluated for HBV resistance testing, with regards to sequencing accuracy and turn-around time. We performed amplicon sequencing of the HBV polymerase gene from patient plasma and external quality assessment (EQA) samples on the MiSeq Reagent Nano Kit v2 and GridION ONT with R10.4.1 flowcells. Mutational analysis and genotyping were performed by DeepChek®Assay-HBV (version 2.0). A total of 49 patient samples and 15 EQA samples were tested on both the MiSeq and ONT. There was high agreement for both patient and EQA samples between the MiSeq and ONT systems, with regards to total drug resistance mutations detected and total patient sample agreement, 68/70 (97 %) and 47/49 (96 %), respectively. The ONT NGS platform provided accurate HBV AVR results, with improved turn-around times. Sequencing error rates at AVR codons were below 1 %.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.022

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.224
GPT teacher head0.430
Teacher spread0.206 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Clinical VirologySame topicHepatitis B Virus StudiesFrench-language works237,207