A Precessing-Coin-like Rotary Actuator for Distal Endoscope Scanners: Proof-of-Concept Study

2025· article· en· W4406620349 on OpenAlexafffund
Nirvana Gharib, Mohammad Reza Yousefi Darestani, Kenichi Takahata

Bibliographic record

VenueMicromachines · 2025
Typearticle
Languageen
FieldEngineering
TopicOptical Coherence Tomography Applications
Canadian institutionsUniversity of British Columbia
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsScannerActuatorOpticsMiniaturizationOptical coherence tomographyVoice coilPhysicsComputer scienceElectromagnetic coilEngineeringElectrical engineeringArtificial intelligence

Abstract

fetched live from OpenAlex

This paper presents, for the first time, a rotary actuator functionalized by an inclined disc rotor that serves as a distal optical scanner for endoscopic probes, enabling side-viewing endoscopy in luminal organs using different imaging/analytic modalities such as optical coherence tomography and Raman spectroscopy. This scanner uses a magnetic rotor designed to have a mirror surface on its backside, being electromagnetically driven to roll around the cone-shaped hollow base to create a motion just like a precessing coin. An optical probing beam directed from the probe's optic fiber is passed through the hollow cone to be incident and bent on the back mirror of the rotating inclined rotor, circulating the probing beam around the scanner for full 360° sideway imaging. This new scanner architecture removes the need for a separate prism mirror and holding mechanics to drastically simplify the scanner design and thus, potentially enhancing device miniaturization and reliability. The first proof-of-concept is developed using 3D printing and experimentally analyzed to reveal the ability of both angular stepping at 45° and high-speed rotation up to 1500 rpm within the biologically safe temperature range, a key function for multimodal imaging. Preliminary optical testing demonstrates continuous circumferential scanning of the laser beam with no blind spot caused by power leads to the actuator. The results indicate the fundamental feasibility of the developed actuator as an endoscopic distal scanner, a significant step to further development toward advancing optical endoscope technology.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.346
Threshold uncertainty score0.755

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.263
Teacher spread0.256 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueMicromachinesSame topicOptical Coherence Tomography ApplicationsFrench-language works237,207