MétaCan
Menu
Back to cohort
Record W4406669666 · doi:10.1002/lio2.70081

Smartphone Thermal Imaging as an Adjunct to Identify Free Flap Perforators and Assisting Flap Design: A Pilot Study

2025· article· en· W4406669666 on OpenAlexaff
Ahmed Saleem, Jonas Philteos, Shayanne A. Lajud, Ashok R. Jethwa, Carissa M. Thomas, Christopher M. K. L. Yao, David P. Goldstein, Kevin Higgins

Bibliographic record

VenueLaryngoscope Investigative Otolaryngology · 2025
Typearticle
Languageen
FieldMedicine
TopicReconstructive Surgery and Microvascular Techniques
Canadian institutionsSunnybrook Health Science CentreUniversity Health NetworkUniversity of OttawaUniversity of Toronto
Fundersnot available
KeywordsMedicineFree flapHead and neckSurgeryThoracodorsal arteryUltrasoundDoppler effectNuclear medicineRadiology

Abstract

fetched live from OpenAlex

ABSTRACT Background The main technique for identification of free flap perforator vessels is Doppler sonography, which is not always accurate, user dependent and affected by the patient's body habitus. Methods Adult patients undergoing head and neck resection and free flap reconstruction at two academic institutions were enrolled. Doppler sonography was used to identify perforators, and were marked using a skin marker. The donor site was cooled down for 3 min using a sterile iced saline bag. FLIR‐ONE (FLIR Systems Inc., Wilsonville, OR) camera was used to assess for “hot spots” during a 3–5 min period of re‐warming as a surrogate for cutaneous blood flow. The distance between the Doppler signal location, and the “hot spot” was recorded. The position of the perforator was then identified intraoperatively and the distances between the surgical position, the Doppler and “hot spot” were recorded. Results A total of 28 patients were included. For all flap types, FLIR thermal imaging measurements consistently tended to be closer to the surgical site compared to Doppler ultrasound. In anterolateral thigh flaps (n = 20), thoracodorsal artery perforator flaps (n = 5), and fibula osteocutaneous flaps (n = 3), absolute mean differences ranged from 0.62 to 1.33 cm, with trends favoring FLIR. While paired t‐tests did not reach statistical significance, both methods correlated with intraoperatively identified skin perforators, and distances generally ranged between 0 and 2 cm. Conclusion We demonstrate that a smartphone‐based thermal imaging system has the potential to serve as an adjunct for identifying flap perforators, with the possibility of reducing operative times and minimizing patient morbidity. Level of Evidence Level 3.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.328
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueLaryngoscope Investigative OtolaryngologySame topicReconstructive Surgery and Microvascular TechniquesFrench-language works237,207