MétaCan
Menu
Back to cohort
Record W4406741956 · doi:10.1016/j.cjco.2025.01.015

Safety and Efficacy of Stereotactic Cardiac Radio-Ablation for Ventricular Tachycardia in Patients at High Risk of Mortality

2025· article· en· W4406741956 on OpenAlexafffund
Calum J. Redpath, Andrew Crean, Pablo B. Nery, Girish M. Nair, Mehrdad Golian, Simon P. Hansom, Connor Haberl, Robert A. deKemp, Phillip S. Cuculich, Clifford G. Robinson, Katie Lekx‐Toniolo, David Tiberi, Graham Cook

Bibliographic record

VenueCJC Open · 2025
Typearticle
Languageen
FieldMedicine
TopicCardiac Arrhythmias and Treatments
Canadian institutionsOttawa HospitalUniversity of Ottawa
FundersUniversity of Ottawa Heart Institute FoundationUniversity of OttawaOntario Ministry of Health and Long-Term CareMinistry of Health, Ontario
KeywordsMedicineVentricular tachycardiaInternal medicineCardiology

Abstract

fetched live from OpenAlex

Background: Patients who have recurrent ventricular tachycardia (VT) despite receiving antiarrhythmic drugs (AADs), implantable cardioverter defibrillator placement, and catheter ablation (CA) are at significant risk of morbidity and mortality. Methods: We offered completely noninvasive cardiac radio-ablation (CRA) on a "compassionate use" basis for patients who were unable or unwilling to undergo CA for recurrent VT despite their having received treatment with AADs and placement of an implantable cardioverter defibrillator. All patients who were referred to the CRA program were entered into a prospective registry and followed indefinitely thereafter. Results: A total of 20 patients were referred for CRA, and 10 elected to undergo the treatment as outpatients. Ten patients declined CRA therapy, owing to fear of complications and/or logistic concerns relating to attending multiple hospital visits; they received escalated drug therapy. All patients who were referred to and were agreeable to CRA received CRA. No patients were excluded or were denied CRA by clinicians for any reason, and all patients were followed clinically. The VT burden decreased significantly, by > 90% (both anti-tachycardia pacing and shocks), and 1 patient died of a cardiovascular cause at 1 year following a single CRA treatment of 25 Gy. One patient experienced steroid-responsive pneumonitis as an adverse event post-CRA (common terminology criteria for adverse events [CTCAE] grade 2). For the 10 patients who declined CRA, no appreciable reduction in VT occurred, despite their receipt of increasing dosages of AADs, and 5 patients died of cardiovascular causes within 1 year. Conclusions: Noninvasive stereotactic CRA is well tolerated with good short-term efficacy for recurrent VT on a "compassionate use" basis. Prospective randomized controlled trials to determine the relative efficacy of CA vs CRA for VT are urgently required.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.010
Threshold uncertainty score0.331

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.290
Teacher spread0.280 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueCJC OpenSame topicCardiac Arrhythmias and TreatmentsFrench-language works237,207