MétaCan
Menu
Back to cohort
Record W4406862636 · doi:10.1002/mrm.30444

Transient shear wave elastometry using a portable magnetic resonance sensor

2025· article· en· W4406862636 on OpenAlexafffund
William Selby, Phil Garland, Igor V. Mastikhin

Bibliographic record

VenueMagnetic Resonance in Medicine · 2025
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsUniversity of New Brunswick
FundersNatural Sciences and Engineering Research Council of CanadaNew Brunswick Innovation Foundation
KeywordsMagnetic resonance elastographyAcousticsMaterials scienceWaveformStiffnessBiomedical engineeringShear wavesElasticity (physics)ElastographyShear (geology)MagnetWave speedNuclear magnetic resonanceUltrasoundComputer sciencePhysicsMedicineTelecommunications

Abstract

fetched live from OpenAlex

PURPOSE: Magnetic resonance elastography (MRE) provides detailed maps of tissue stiffness, helping to diagnose various health conditions, but requires the use of expensive clinical MRI scanners. Our approach utilizes compact, cost-effective portable MR sensors that offer bulk characterization of material properties in a region of interest close to the surface (within 1-2 cm). This accessible instrument could enable routine monitoring and prevention of diseases not readily evaluated with conventional tools. METHODS: The method was tested on tissue-mimicking phantoms with varying stiffness. The gels were excited with acoustic pulses (one cycle of a sinusoidal waveform) at a fixed distance from the MR sensor. A series of delays between acoustic excitation and MR signal detection allowed time for the pulse to travel to the sensitive region. RESULTS: The "arrival time" of the shear wave, determined by the time-dependent MR signal response, was used to calculate the shear wave speed. MR measurements of shear wave speed were compared with optical sensor measurements and manufacturer-tabulated values, aligning with expected relative differences between samples. CONCLUSION: A portable MR-based transient elastometry technique for measuring tissue elasticity was developed and demonstrated on tissue-mimicking phantoms. Future improvements include using a new portable magnet to investigate depth-dependent changes in elasticity in stratified samples and integrating MR relaxation and diffusion measurements for comprehensive tissue analysis. This approach can complement conventional MRE in applications where a portable, affordable, and localized assessment of tissue stiffness is required.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.277
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicUltrasound Imaging and ElastographyFrench-language works237,207