MétaCan
Menu
Back to cohort
Record W4406973711 · doi:10.1016/j.brachy.2024.12.001

3D-printed radiopaque episcleral plaques with radioactive collimating cavities for enhanced dose delivery in brachytherapy

2025· article· en· W4406973711 on OpenAlexafffund
Souheib Zekraoui, Théophraste Lescot, Mahdokht Akbari Taemeh, Marc‐André Fortin

Bibliographic record

VenueBrachytherapy · 2025
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsCentre hospitalier de l'Université Laval
FundersNatural Sciences and Engineering Research Council of CanadaFonds de recherche du Québec – Nature et technologiesCanadian Institutes of Health Research
KeywordsMedicineBrachytherapy3d printedCollimated lightNuclear medicineRadiologyMedical physicsBiomedical engineeringRadiation therapyOptics

Abstract

fetched live from OpenAlex

PURPOSE Episcleral plaque brachytherapy (EPBT) is a well-established treatment. However, the lateral dose to healthy tissues, such as the sclera, retina, and optic nerve is often problematic and results in side effects. This study proposes an innovative approach based on the 3D-printing of radiopaque polymer plaques featuring cylindrical radioactive cavities (CRC) with a potential collimating effect on radiation delivery to tumors. METHODS AND MATERIALS A CAD model based on the COMS protocol was created and 3D-printed using radiopaque PEEK polymer. Cylindrical cavities (1 mm depth/diameter) were evenly spaced on the plaque's inner surface. Two radioactive layouts (RL 1 : uniform loading; RL 2 : radial gradient loading) were designed. µCT imaging was used to assess the geometric accuracy of the 3D-printed CRC EPs, and dose distribution was evaluated for the two (2) radioactive layouts using MAGIC-pf gel dosimetry and T 2 -weighted MRI. The resulting dose profiles were compared with those generated by both COMS and SEP plaques. RESULTS Radiopaque CRC EPs showed higher central axis dose deposition while minimizing lateral overexposure compared to COMS and SEP plaques, while also providing robust back-shielding. Dose profiles from RL 1 CRC EPs (uniform layout) extended deeper into the eye, whereas RL 2 CRC EPs (with gradient) exhibited a more rapid dose fall-off, producing a concentrated, spherical dose distribution. CONCLUSIONS 3D-printed radiopaque EPs with radioactivity encapsulated in cylindrical cavities demonstrated the ability to achieve more forward-projected dose profiles in EPBT. This fabrication design and a modulated radioactivity distribution across the EP surface would enable more precise and deeper dose delivery while reducing radiation exposure to lateral healthy tissues.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.632
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.278
Teacher spread0.271 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueBrachytherapySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207