MétaCan
Menu
Back to cohort
Record W4407000021 · doi:10.1088/1741-2552/adab22

Enhancing transcranial ultrasound stimulation planning with MRI-derived skull masks: a comparative analysis with CT-based processing

2025· article· en· W4407000021 on OpenAlexafffund
Ali K. Zadeh, Oula Puonti, Björn Sigurðsson, Axel Thielscher, Oury Monchi, Samuel Pichardo

Bibliographic record

VenueJournal of Neural Engineering · 2025
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsInstitut Universitaire de Gériatrie de MontréalHotchkiss Brain InstituteUniversité de MontréalUniversity of Calgary
FundersNatural Sciences and Engineering Research Council of CanadaEuropean CommissionCanada Foundation for InnovationInnovationsfonden
KeywordsUltrasoundSkullMagnetic resonance imagingSegmentationMedicineTomographyComputer science3D ultrasoundRadiologyNuclear medicineArtificial intelligenceAnatomy

Abstract

fetched live from OpenAlex

Abstract Objective. Transcranial ultrasound stimulation (TUS) presents challenges in ultrasound wave transmission through the skull, affecting study outcomes due to aberration and attenuation. While planning strategies incorporating 3D computed tomography (CT) scans help mitigate these issues, they expose participants to radiation, which can raise ethical concerns. A solution involves generating skull masks from participants’ anatomical magnetic resonance imaging (MRI). This study aims to compare ultrasound field predictions between CT-derived and MRI-derived skull masks in TUS planning. Approach. Five participants with a range of skull density ratios (SDRs: 0.31, 0.42, 0.55, 0.67, and 0.79) were selected, each having both CT and T1/T2-weighted MRI scans. Ultrasound simulations were performed using BabelBrain software with a single-element transducer (diameter = 50 mm, F # = 1) at 250, 500, and 750 kHz frequencies. CT scans were used to generate maps of the skull’s acoustic properties. The MRI scans were processed using the Charm segmentation tool from the SimNIBS tool suite using default and custom settings adapted for better skull segmentation. Ultrasound was adjusted to target 30 mm below the skull’s surface at 54 electroencephalogram (EEG) locations. Main Results. The custom setting in Charm significantly improved the Dice coefficient between MRI- and CT-derived masks when compared to the default setting ( p < 0.001). The maximum pressure error significantly decreased in the custom setting compared to the default setting ( p < 0.001). Additionally, the focus location error median across different SDRs averaged 2.32, 1.45, and 1.57 mm in default and 2.08, 1.38, and 1.44 mm in custom conditions for 250 kHz, 500 kHz, and 750 kHz respectively. Significance. MRI-derived skull masks offer satisfactory accuracy at many EEG sites, and using custom settings can further enhance this accuracy. However, significant errors at specific locations highlight the importance of carefully considering stimulation location when choosing between CT- and MRI-derived skull modeling.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.435
Threshold uncertainty score0.735

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.239
Teacher spread0.229 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Neural EngineeringSame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207