MétaCan
Menu
Back to cohort
Record W4407243502 · doi:10.1016/j.jocmr.2025.101856

Multiresolution comparison of fetal real-time and cine magnetic resonance imaging at 0.55T

2025· article· en· W4407243502 on OpenAlexafffund
Datta Singh Goolaub, Ye Tian, Joshua van Amerom, John C. Wood, Jon Detterich, Krishna S. Nayak, Christopher K. Macgowan

Bibliographic record

VenueJournal of Cardiovascular Magnetic Resonance · 2025
Typearticle
Languageen
FieldMedicine
TopicFetal and Pediatric Neurological Disorders
Canadian institutionsUniversity of TorontoHospital for Sick ChildrenSickKids Foundation
FundersEunice Kennedy Shriver National Institute of Child Health and Human DevelopmentCanadian Institutes of Health ResearchUniversity of South ChinaUniversity of Southern California
KeywordsUndersamplingMedicineImage qualityNuclear medicineSteady-state free precession imagingBiomedical engineeringArtificial intelligenceRadiologyMagnetic resonance imagingComputer scienceImage (mathematics)

Abstract

fetched live from OpenAlex

BACKGROUND: Dynamic fetal cardiovascular MRI (CMR) enables visualization of moving structures to assess congenital heart disease and plan treatment. Low field MRI systems can provide more comfortable platforms for fetal CMR. Here, we demonstrate the feasibility and utility of motion corrected fetal cardiac cine CMR and compare it with real-time CMR at multiple spatial resolutions at 0.55 T. METHODS: Ten human pregnancies were scanned at 0.55T on a derated MAGNETOM Aera (Siemens Healthineers, Erlangen, Germany) with spiral steady-state free precession imaging. Real-time images were reconstructed and used for motion correction and fetal cardiac gating followed by cine reconstructions. The signal-to-noise ratio (SNR), image quality, blood-to-myocardium contrast, and contrast-to-noise ratio (CNR) from real-time and cine reconstructions were compared. The effect of acceleration on cine accuracy was assessed by retrospectively undersampling the data and measuring the reconstruction error with the normalized root-mean-squared difference (NRMSD) in five fetuses. Reproducibility of the measurements was assessed by reconstructing cines from two independent windows of data and computing the NRMSD relative to the reference image in five fetuses. RESULTS: The SNR, CNR, and image quality were better for cines than their corresponding real-time reconstructions. The blood-to-myocardium contrast had no significant difference between real-time and cine reconstructions. With finer spatial resolution, real-time images degraded, and cardiac structures were less conspicuous. NRMSD in cines decreased with increasing scan times across all resolutions (NRMSD = 10 ± 2% for 7 s scan duration). Good consistency (NRMSD = 11 ± 3%) was achieved between independent reconstruction windows. CONCLUSION: While this study was performed on an experimental scanner (derated; not commercially available), we have shown that fetal cine CMR is feasible at 0.55T and provides high-quality fetal cardiac images at high spatiotemporal resolutions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.005
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.246
Teacher spread0.237 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Cardiovascular Magnetic ResonanceSame topicFetal and Pediatric Neurological DisordersFrench-language works237,207