MétaCan
Menu
← Back to cohort
Record W4407254945 · doi:10.1111/cid.70003

Influence of Implant Geometry on the Surface Strain Behavior of Peri‐Implant Bone: A <scp>3D</scp> Analysis

2025· article· en· W4407254945 on OpenAlexvenueno aff
Moritz Löhlein, Constantin Motel, Manfred Wichmann, Ragai Edward Matta

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2025
Typearticle
Languageen
FieldDentistry
TopicDental Implant Techniques and Outcomes
Canadian institutionsnot available
Fundersnot available
KeywordsImplantPeriStrain (injury)DentistryMaterials scienceMedicineAnatomySurgery

Abstract

fetched live from OpenAlex

To ensure long-term implant success, it is crucial to understand the force transmission from the implant to the surrounding bone. In dentistry, bioengineering methods are applied to investigate these processes. The aim of this study was to analyze the influence of different implant geometries on the surface strain behavior of porcine mandibles under load using a 3D optical camera system in combination with digital image correlation. Four different implant types were subjected to a force of 200 N in three different loading directions (axial, non-axial 15°, and non-axial 30°). Under axial loading, parallel-walled implants exhibited lower surface strain values on the peri-implant bone compared with tapered implants. However, when subjected to non-axial loading, these parallel-walled implants showed a substantial relative increase in strain by approximately a factor of 2.96 compared with axial conditions. At a 30° non-axial angle, long, tapered implants with a smaller diameter (BLX 3.75) produced lower peri-implant bone strains than implants with larger diameters and shorter lengths, while short, tapered implants (BLT) demonstrated a lower relative increase in strain (factor ~1.49) from axial to non-axial loading. Under non-axial loading, long, tapered implants with a small diameter resulted in lower strains in the peri-implant bone compared with implants with a larger diameter and shorter length. It was found that non-axial loads lead to higher strains than axial loads. Therefore, the success of implantation could be significantly influenced by selecting an appropriate implant geometry and the correct angulation of the implant.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.077
GPT teacher head0.450
Teacher spread0.374 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related Research→Same topicDental Implant Techniques and Outcomes→French-language works237,207→