MétaCan
Menu
Back to cohort
Record W4407296526 · doi:10.1177/17442591251317727

Data-driven modelling of pressurized corridor ventilation system performance in a multi-unit residential building

2025· article· en· W4407296526 on OpenAlexafffundabout
Helen Stopps, Cara H. Lozinsky, Marianne F. Touchie

Bibliographic record

VenueJournal of Building Physics · 2025
Typearticle
Languageen
FieldEnvironmental Science
TopicWind and Air Flow Studies
Canadian institutionsUniversity of TorontoCarleton UniversityToronto Metropolitan University
FundersNatural Sciences and Engineering Research Council of CanadaAmerican Society of Heating, Refrigerating and Air-Conditioning Engineers
KeywordsCabin pressurizationDoorsEnvironmental scienceUnit (ring theory)Ventilation (architecture)AirflowEngineeringMarine engineeringStructural engineeringMechanical engineering

Abstract

fetched live from OpenAlex

Pressurized corridor (PC) ventilation systems are a common method used in existing multi-unit residential buildings (MURBs) to deliver make-up air to individual units, and as a means of controlling inter-zonal odour/contaminant transfer. In PC systems, ventilation air is supplied directly to the common corridor and enters the units via intentional undercuts at the unit entry doors. In practice, the amount of ventilation air supplied to each unit is dependent on the air pressure differential between the two zones, which can be affected by occupant behaviours, such as window and unit exhaust fan operation; wind; or large indoor-outdoor temperature differentials. Accurately characterizing the impact of these variables on building pressure differentials is critical to not only identifying conditions when depressurization events may occur (which would result in a lack of ventilation to dwelling unit and the potential for contaminant movement from units to the corridor), but also understanding how operational changes can improve system operation. This paper will describe the development of an XGBoost regression model for predicting inter-zonal pressure differentials in a contemporary MURB with a PC system. The model was trained and validated using measurements collected as part of a 6-month field study in a 17-storey MURB located in Toronto, Canada, including corridor-to-unit and exterior-to-unit differential pressures, window/door operation, corridor supply air flow rates and interior/exterior temperature and relative humidity. Unit exhaust fan operation was inferred from the unit differential pressure data. This paper addresses feature selection, hyperparameter tuning and accuracy assessment, with a specific emphasis on evaluating the potential for the use of the model as a diagnostic tool and testing environment to evaluate ventilation system performance in multi-unit residential buildings.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.164
Threshold uncertainty score0.392

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.060
GPT teacher head0.290
Teacher spread0.229 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2025
Admission routes3
Has abstractyes

Explore more

Same venueJournal of Building PhysicsSame topicWind and Air Flow StudiesFrench-language works237,207