MétaCan
Menu
Back to cohort
Record W4407341841 · doi:10.3390/su17041393

Comparison and Design of Dry-Stack Blocks with High Thermal Resistance for Exterior Walls of Sustainable Buildings in Cold Climates

2025· article· en· W4407341841 on OpenAlexafffund
Tesfaalem Gereziher Atsbha, Yuxiang Chen

Bibliographic record

VenueSustainability · 2025
Typearticle
Languageen
FieldEngineering
TopicMasonry and Concrete Structural Analysis
Canadian institutionsUniversity of Alberta
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsThermal resistanceMasonryThermal bridgeThermal insulationStructural engineeringBlock (permutation group theory)Composite numberBuilding envelopeThermalEngineeringMaterials scienceEnvironmental scienceComposite materialLayer (electronics)Mathematics

Abstract

fetched live from OpenAlex

Given the increasing demand for higher construction productivity and better thermal resistance, adopting innovative building envelope systems is crucial. Dry-stack masonry blocks have emerged as a viable solution, due to their rapid assembly, mortar-free construction, and reduced dependence on skilled labor. However, there is a lack of scientific evaluation on the thermal performance of dry-stack blocks for cold climate zones and corresponding proper designs. This study addresses this gap by investigating market-available blocks and proposing two innovative block designs—a composite block and a simple block—highlighting their thermal performance and associated challenges. Using finite element modelling, the thermal resistance of these blocks was carefully assessed and compared. The results show that thermal bridging, induced by masonry ties penetrating the insulation, significantly impacts the thermal resistance of the wall made with simple blocks, resulting in an 11% decrease in the effective thermal resistance (R-value) as compared to the composite block walls. Furthermore, compared to a conventional masonry wall with the same insulation thickness, the composite-block wall exhibits a 24% higher R-value. The composite block outperforms existing market options in terms of thermal resistance, making it a superior choice for cold climate regions. Conversely, the simple block is preferred when sophisticated manufacturing facilities are unavailable. Overall, the composite block wall’s improved thermal resistance can make a meaningful contribution to lowering operational energy demand (i.e., operational carbon), contributing to the shift to a sustainable building stock.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.436
Threshold uncertainty score0.545

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.235
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueSustainabilitySame topicMasonry and Concrete Structural AnalysisFrench-language works237,207