MétaCan
Menu
Back to cohort
Record W4407521568 · doi:10.1021/jasms.4c00400

Unveiling Readily Ionized and Robust Anionic Species: A Gateway to Enhanced Ionization Efficiency in ESI-MS Analysis

2025· article· en· W4407521568 on OpenAlexafffund
Benjamin Warnes, Jasmine Chihabi, Jeffrey M. Manthorpe

Bibliographic record

VenueJournal of the American Society for Mass Spectrometry · 2025
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsCarleton University
FundersNatural Sciences and Engineering Research Council of CanadaCarleton University
KeywordsChemistryIonizationElectrospray ionizationMass spectrometryGateway (web page)ChromatographyAmbient ionizationAnalytical Chemistry (journal)Chemical ionizationIonOrganic chemistryWorld Wide Web

Abstract

fetched live from OpenAlex

Electrospray ionization mass spectrometry has long been a prevalent ionization method in the analysis of low volatility molecules with biological, environmental, and industrial relevance. To address analytical challenges associated with molecules suffering from low ionization efficiencies (IEs), chemical derivatization (CD) strategies have been developed and are frequently adopted into workflows. However, only a minute number of CD techniques have been developed for negative polarity. To address this disparity, we evaluated 27 anions based on three criteria: (1) IE relative to a sodium dodecyl sulfate ( 11 + Na + ) internal standard; (2) stability to collision induced dissociation; (3) diagnostic tandem mass spectrometry behavior. Highly fluorous ions exhibiting weakly coordinating and hydrophobic properties displayed enhanced IE. Trifluoromethanesulfonyl-containing ions proved to be unexpectedly labile, while tetrakis[3,5-bis(trifluoromethyl)phenyl]borate ( 23 ) and bis(nonafluoro-1-butane)sulfonimidate ( 25 ) were determined to be of optimal IE of 332% ± 25% and 939% ± 92%, respectively, and in tandem MS exhibited survival yields of 100% ± 0% and 72.6% ± 0.8% at −50 eV. 23 and 25 were also comparable in IE across several solvents, and combinations thereof, that are ubiquitous in liquid chromatography. Various salts of 25 were evaluated for cation effects, where the IE of 25 ranged from 939% ± 92% to 3195% ± 145% across K +, NH 4 +, Na +, and H + . Compared to tetra- n -butylammonium, tetra- n -butylphosphonium, and (4-methylphenyl)diphenylsulfonium cations, 25 displayed signal enhancements ranging from 136% ± 6% to 181% ± 14%, thereby making it an optimal candidate for CD development.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.266
Teacher spread0.257 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueJournal of the American Society for Mass SpectrometrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207