MétaCan
Menu
Back to cohort
Record W4407798990 · doi:10.1002/adhm.202404193

Continuous High‐Throughput Plasma Separation for Blood Biomarker Sensing Using a Hydrodynamic Microfluidic Device

2025· article· en· W4407798990 on OpenAlexafffund
Hesam Abouali, Fatemeh Keyvani, Seied Ali Hosseini, Sanjana Srikant, Mahla Poudineh

Bibliographic record

VenueAdvanced Healthcare Materials · 2025
Typearticle
Languageen
FieldEngineering
TopicMicrofluidic and Bio-sensing Technologies
Canadian institutionsUniversity of Waterloo
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of Waterloo
KeywordsMicrofluidicsAptamerSeparator (oil production)Materials scienceHemolysisChromatographyBiosensorPlasmaWhole bloodNanotechnologyYield (engineering)Detection limitCentrifugationChemistry

Abstract

fetched live from OpenAlex

Continuous, cost-effective, high-throughput with admissible yield and purity of blood plasma separation is widely needed for biomarker detection in the clinic. The existing gold standard technique (centrifugation) and microfluidic technologies fall short of meeting these criteria. In this study, a microfluidic device design is demonstrated based on passive hydrodynamic principles to achieve admissible yield and purity plasma samples. Through computational and experimental assessments, it is shown that side channels with varying lengths are required to improve the plasma extraction rate. The optimized side channels in this device design use the formed cell-free layer regions in the expanded areas to extract plasma consistently and efficiently. These Hydrodynamic Continuous, High-Throughput Plasma Separator (HCHPS) microfluidic devices achieve a purity in the range of 47% to 64% with whole blood and maintaining a yield of 10% to 18%, with half hemolysis compared to gold standard centrifugation. These devices also separate the plasma from diluted blood with a purity in the range of 62% to 97% with a similar yield range. Additionally, whole human blood spiked with lactate was processed through the HCHPS device, and the separated plasma is collected and analyzed using two biosensing approaches, a bead-based fluorescence, and an electrochemical aptamer biosensing, confirming the quality of plasma for downstream biomarker detection.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.013
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.301
Teacher spread0.282 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations10
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueAdvanced Healthcare MaterialsSame topicMicrofluidic and Bio-sensing TechnologiesFrench-language works237,207