MétaCan
Menu
Back to cohort
Record W4407860483 · doi:10.1002/acm2.70019

The effect of kV imaging dose on PTV and OAR planning constraints in lung SBRT using stereoscopic/monoscopic real‐time tumor‐monitoring system

2025· article· en· W4407860483 on OpenAlexaff
Ruwan Abeywardhana, Mike Sattarivand

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2025
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsNova Scotia Health AuthorityDalhousie University
Fundersnot available
KeywordsMedicineRadiation treatment planningNuclear medicineImage-guided radiation therapyMedical imagingRadiation therapyRadiology

Abstract

fetched live from OpenAlex

PURPOSE: Quantify the impact of additional imaging doses on clinical dose constraints during lung stereotactic body radiotherapy (SBRT) treatment utilizing stereoscopic/monoscopic real-time tumor monitoring. MATERIALS AND METHODS: Thirty lung SBRT patients treated with the volumetric arc therapy technique were randomly selected from the institutional clinical database. Contours of patients' and computed tomography data were extracted from the Eclipse treatment planning system, along with information regarding the treatment dose. Subsequently, patient-specific three-dimensional real-time imaging dose distributions were computed using a validated Monte Carlo simulation of the ExacTrac imaging. The 3D imaging dose was added to the treatment dose, and the influence of the imaging dose on clinical dose constraints was analyzed for planning target volume (PTV) and various organs at risk (OARs). RESULTS: Among the 30 patients, 14 patients exhibited one or more failed OAR constraints based solely on the treatment dose, resulting in a total of 24 constraint failures. The addition of the real-time imaging dose altered the pass/fail criteria for one OAR constraint and two PTV constraints. The change in constraint due to additional imaging dose relative to the prescription dose was less than 1% for all patients, except for one case, where it reached 1.9%, which had remained below the threshold of 5% recommended by AAPM TG-180 guidelines. Furthermore, the additional imaging dose relative to the treatment dose resulted in an increase in OAR constraints ranging from 0 to 27% (mean of 0.8%), with nine cases exceeding 5%. CONCLUSION: The current study represents the first attempt to investigate the impact of additional imaging doses on clinical planning constraints in real-time tumor monitoring during lung SBRT utilizing ExacTrac imaging system. The addition of an imaging dose will likely have minimal clinical impact.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.497
Threshold uncertainty score0.569

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.376
Teacher spread0.364 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207