MétaCan
Menu
Back to cohort
Record W4408126894 · doi:10.1002/mrm.30436

<scp>3D MERMAID</scp> : <scp>3D</scp> Multi‐shot enhanced recovery motion artifact insensitive diffusion for submillimeter, multi‐shell, and <scp>SNR</scp> ‐efficient diffusion imaging

2025· article· en· W4408126894 on OpenAlexafffund
Sajjad Feizollah, Christine Tardif

Bibliographic record

VenueMagnetic Resonance in Medicine · 2025
Typearticle
Languageen
FieldMedicine
TopicAdvanced Neuroimaging Techniques and Applications
Canadian institutionsMcGill UniversityMcGill University Health CentreMontreal Neurological Institute and Hospital
FundersFonds de recherche du Québec – Nature et technologiesFonds de Recherche du Québec - SantéNatural Sciences and Engineering Research Council of CanadaFondation Brain Canada
KeywordsImaging phantomFlip anglePhysicsPulse sequenceArtifact (error)ScannerOpticsSingle shotDiffusionNuclear magnetic resonanceMaterials scienceComputer scienceComputer visionMagnetic resonance imaging

Abstract

fetched live from OpenAlex

Abstract Purpose To enhance SNR per unit time of diffusion MRI to enable high spatial resolution and extensive q‐sampling in a feasible scan time on clinical scanners. Methods 3D multi‐shot enhanced recovery motion‐insensitive diffusion (MERMAID) consists of a whole brain nonselective 3D multi‐shot spin‐echo sequence with an inversion pulse immediately before the excitation pulse to enhance the recovery of longitudinal magnetization. The excitation flip angle is reduced to the Ernst angle. The sequence includes a trajectory using radially batched internal navigator echoes (TURBINE) readout, where a 3D projection of the FOV is acquired at a different radial angle in every shot. An image‐based phase‐correction method combined with compressed sensing image reconstruction was developed to correct phase errors between shots. The performance of the 3D MERMAID sequence was investigated using Bloch simulations as well as phantom and human scans at 3 T and then compared to a typical multi‐slice 2D spin‐echo sequence. Results Improvements in SNR per unit time of 70%–240% were observed in phantom and human scans when using 3D MERMAID compared to a single‐slice 2D spin‐echo sequence. This SNR per unit time improvement allowed scans to be acquired at a nominal isotropic resolution of 0.74 mm and a total of 112 directions across four shells ( b = 150, 300, 1000, 2000 s/mm 2 ) in 37 min on a clinical scanner. Conclusion The 3D MERMAID sequence was shown to significantly improve SNR per unit time compared to multi‐slice 2D and 3D diffusion sequences. This SNR improvement allows for shorter scan times and higher spatial and angular resolutions on clinical scanners.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.006
Threshold uncertainty score0.020

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.037
GPT teacher head0.324
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced Neuroimaging Techniques and ApplicationsFrench-language works237,207