MétaCan
Menu
Back to cohort
Record W4408223934 · doi:10.1016/j.adro.2025.101752

A Feasibility Study for Clinical Implementation of hypo fractionated SBRT Program at a Clinic in an LMIC Using Locally Designed Lung Phantom

2025· article· en· W4408223934 on OpenAlexaff
Abigail N. M. Quaye, Eric C D K Addison, Ernest Osei, Afua Yorke

Bibliographic record

VenueAdvances in Radiation Oncology · 2025
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsGrand River Hospital
FundersAmerican Association of Physicists in Medicine
KeywordsMedicineImaging phantomMedical physicsLungNuclear medicineInternal medicine

Abstract

fetched live from OpenAlex

This study aims to assess the feasibility of implementing a hypofractionated radiation therapy (HFRT) program at the Oncology Directorate of Komfo Anokye Teaching Hospital in Ghana, addressing specific infrastructure limitations that hinder patient care and treatment efficiency. Hence, we conducted a feasibility study to start a HFRT lung stereotactic body radiation therapy (SBRT) program using currently available resources. The goal is to alleviate the burden on patients and health care providers, particularly in the context of limited resources. A lung phantom was designed from locally sourced materials consisting of wood slabs to mimic the lung, a perspex tank filled with water for tissue equivalence, and a 3-cm diameter acrylic ball to simulate the tumor. A motion platform was also designed for the phantom to simulate patients breathing in the superior-inferior direction. We acquired 3 computed tomography (CT) scan data sets using a slow CT scan technique for target motions of 0 cm (no_target_motion), 0.5 cm (0.5-cm_target_motion), and 1 cm (1-cm_target_motion) displacements. Treatment plans were generated for each phantom CT image data set using 9-field 6-Mega-Voltage (MV) photon beams in the eclipse treatment planning system. We also generated a treatment plan using an actual patient CT data set to assess the doses to target in the lung and critical organs at risk during a typical lung SBRT treatment. The quality of each treatment plan was evaluated using the near maximum (D 2% ), near minimum (D 98% ), mean (D mean ), V 100 , V 95 , V 90 , heterogeneity index (HI), conformity index (CI), the ratio of 50% prescription isodose volume to the PTV volume, (R 50% ), maximum dose (in % of dose prescribed) at 2 cm from PTV in any direction (D 2cm , Gy) and dose-volume-histograms for the planning target volume (PTV). The near maximum (D 2% ), mean, V 5 , V 10 , V 15 , and V 20 values were used as the dose metrics to evaluate the dose to the lung. Maximum dose was used to evaluate the dose to the spinal cord, and the maximum and mean doses were used to evaluate doses to the esophagus, heart, trachea, and ribs. We quantitatively assessed the quality of the phantom treatment plans by calculating the CI, HI, R 50%, and D 2cm for each plan. The CI values for the PTV for the no_target_motion, 0.5-cm_target_motion, and 1-cm_target_motion are 1.07, 1.08, and 1.06, respectively. The HIs for the PTV for no_target_motion, 0.5-cm_target_motion, and 1-cm_target_motion are 1.20, 1.10, and 1.20 respectively. The R 50% for the no_target_motion, 0.5-cm_target_motion, and 1-cm_target_motion are 3.98, 3.86, and 3.82, respectively, and the corresponding D 2cm values are 27.30, 31.64, and 30.47, respectively. The CI, HI, R 50%, and D 2cm values for the PTV using the actual patient CT data set are 1.08, 1.22, 7.1, and 58.7 respectively. Therefore, our data demonstrate good dose conformity and heterogeneity within the PTV, with a sharp dose fall-off for all cases. The point dose measurements made in the phantom also show good agreement with treatment planning data. Our results demonstrate that implementing HFRT using 3-dimensional conformal radiation therapy for lung SBRT is feasible with the current infrastructure of our institution. Although the proposed treatment plan is effective, future research on motion management and image guidance technologies is necessary to optimize treatment fidelity. These findings suggest that HFRT could be a viable option for addressing resource constraints in radiation therapy delivery in similar settings.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.271
Threshold uncertainty score0.601

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.060
GPT teacher head0.568
Teacher spread0.509 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueAdvances in Radiation OncologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207