MétaCan
Menu
Back to cohort
Record W4408244428 · doi:10.1002/acm2.70023

Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac

2025· article· en· W4408244428 on OpenAlexaff
Luis Agulles‐Pedrós, R Lee MacDonald, Amanda Cherpak, Nayha Dixit, Lei Dong, Tianyu Zhao, Kundan Thind, Anthony Doemer, Boon‐Keng Teo, Shiqin Su, Alexander Moncion, James L. Robar

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2025
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsNova Scotia Health Authority
Fundersnot available
KeywordsImage qualityHounsfield scaleNuclear medicineCone beam computed tomographyMathematicsMedicinePhysicsOpticsComputed tomographyComputer scienceRadiologyImage (mathematics)Artificial intelligence

Abstract

fetched live from OpenAlex

Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions. Methods Phantoms for measuring relative electron density (RED) and image quality were sent to six institutions for imaging on Ethos and Halcyon units equipped with HyperSight CBCT. The imaging protocols included tube potential from 100 to 140 kVp and exposure from 80 to 800 mAs. Imaging performance was evaluated with regard to RED versus Hounsfield units (HU), uniformity, contrast‐to‐noise ratio (CNR), slice thickness, circular symmetry, modulation transfer function (MTF), and spatial resolution. Results Among all institutions, some variability was observed among institutions in the RED‐to‐HU relationship, especially for RED values greater than 1, although no outliers were found (| z ‐score| < 2 in all cases). In this range, RED/HU slopes were 475 ± 25 10 −6 RED/HU at 100kVp, 505 ± 20 10 −6 RED/HU at 125kVp, and 550 ± 20 10 −6 RED/HU at 140kVp. Radial uniformity ranged from 1 to 7 HU, depending on protocol. Circular symmetry for two points 50 mm apart showed consistency within one‐pixel dimension. Integral nonuniformity was between 1 and 10, with no difference observed between vertical and horizontal dimensions. Contrast rods with 1% gave CNR = 0.5, 1 and 2 for 100(88), 125(176), and 140(528) in kVp(mAs), and contrast rods with 0.5% had CNR = 0.2, 0.4 and 0.8 for 100(88), 125(176), and 140(528) in kVp(mAs). Spatial resolution given by MTF at 10% and 50% yielded values of 0.55 ± 0.01 mm −1 and 0.35 ± 0.02 mm −1 , respectively. Conclusions This multi‐institutional analysis of CBCT imaging performance showed consistency in radial uniformity, circular symmetry, integral nonuniformity, contrast, and spatial resolution. Some variability was seen in the RED‐to‐HU relationship for RED > 1 depending on exposure. More data from different institutions would be necessary to establish more robust statistical metrics, which ensure quality parameters.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.865
Threshold uncertainty score0.657

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.078
GPT teacher head0.427
Teacher spread0.349 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations9
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced X-ray and CT ImagingFrench-language works237,207