MétaCan
Menu
← Back to cohort
Record W4408468548 · doi:10.1021/acs.analchem.5c00006

An Ultra-High-Resolution Mass Spectrometer with an Intermediate-Pressure Matrix-Assisted Laser Desorption/Ionization Source

2025· article· en· W4408468548 on OpenAlexaff
Zheng-ge Chen, Yi Hong, Li Yang, Bin Hu, Qi Huang, Lei Li, Zhengxu Huang, Li Ding, Zhen Zhou

Bibliographic record

VenueAnalytical Chemistry · 2025
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsIONICS Mass Spectrometry (Canada)
Funders3315 Innovation Team in Ningbo CityNational Key Research and Development Program of China
KeywordsChemistryMass spectrometryAnalytical Chemistry (journal)IonizationOrbitrapResolution (logic)Ion sourceHybrid mass spectrometerMatrix-assisted laser desorption/ionizationSpectrometerAmbient ionizationDetection limitDesorptionSelected reaction monitoringChemical ionizationIonTandem mass spectrometryChromatographyOptics

Abstract

fetched live from OpenAlex

The demand for high-resolution, high-throughput and spatially resolved mass analysis has been a key focus in developing mass spectrometers. We have developed a novel high-performance mass spectrometer by integrating matrix-assisted laser desorption/ionization (MALDI) source with a new planar electrostatic ion trap mass analyzer for ultrahigh-resolution MALDI source mass analysis. Performance characterization experiments show that with a transient time of 800 ms, the resolution for 392 Th can exceed 530 K by utilizing high-order harmonics, and the spectrometer can distinguish the isotopic peaks in the Met-Arg-Phe-Ala acetate salt (MRFA) M+2 peak family. Preliminary results also show an overall mass range from 133 to 9500 Th by stitching together multiple single scans with at least 6-fold mass range, and a low detection limit of 32 fg. Initial tests on analysis of edible oils demonstrate its capability to distinguish plant and animal oils based on triacylglycerols.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.008
Threshold uncertainty score0.025

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0010.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0080.004

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.259
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueAnalytical Chemistry→Same topicMass Spectrometry Techniques and Applications→French-language works237,207→