MétaCan
Menu
Back to cohort
Record W4408587614 · doi:10.1515/labmed-2024-0181

Validation and implementation of an intraoperative parathyroid hormone assay and workflow: practical advice for endocrine surgery centres

2025· article· en· W4408587614 on OpenAlexaffabout
Phillip Staibano, Basma Ahmed, Josko Ivica, Joseph Macri, Michael Au, Han Zhang, Jesse D. Pasternak, Mohit Bhandari, Peter A. Kavsak

Bibliographic record

VenueJournal of Laboratory Medicine · 2025
Typearticle
Languageen
FieldMedicine
TopicParathyroid Disorders and Treatments
Canadian institutionsUniversity of TorontoUniversity Health NetworkHamilton Health SciencesHamilton Regional Laboratory Medicine ProgramMcMaster UniversityImpact
Fundersnot available
KeywordsWorkflowEndocrine surgeryParathyroid hormoneEndocrine systemMedicineAdvice (programming)HormoneComputer scienceInternal medicineDatabaseCalciumThyroid

Abstract

fetched live from OpenAlex

Abstract Objectives Intraoperative PTH (IOPTH) can be challenging to offer through central laboratories despite its clinical benefit. We describe the implementation of a central laboratory-based IOPTH assay and workflow in a tertiary care centre. Methods The Elecsys ® PTH STAT assay was assessed in EDTA plasma on the Cobas ® e411 analyzer. Assay validation included precision, linearity, coefficient of variation (CV), accuracy, stability, and dilution. Samples were transported to the central laboratory and resulted via telephone to the operating room. We describe a case series of patients with primary hyperparathyroidism (PHPT) who underwent parathyroid surgery using our described IOPTH workflow. Results Within- and between-day CV was ≤3.0 % for quality control material that ranged from 2.2–44.6 pmol/L. Passing–Bablok regression yielded a slight proportional negative bias between the two Cobas e411 instruments [Elecsys ® PTH our centre=0.95 (95 % CI: 0.90–1.00) × Elecsys ® PTH Toronto − 0.05 (95 % CI: −0.20 to 0.09) (n=22)], but high correlation (r=0.99) as compared to PTH measured on the Vitros ® XT 7600 analyzer [Elecsys ® PTH=0.91 (95 % CI: 0.73–1.1) × Vitros ® PTH + 0.1 (95 % CI: −0.34 to 0.76), r=0.96 (n=40)]. The mean operating time across ten patients surgically cured for PHPT was 47.1 min (±9.1) and no patients required intraoperative frozen tissue analysis. Conclusions The Elecsys ® PTH STAT assay demonstrated acceptable analytical performance, and the described IOPTH workflow was implemented successfully via a collaborative hospital-wide initiative. We discuss our model to help guide other institutions in implementing and improving IOPTH workflows.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.503
Threshold uncertainty score0.381

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.378
Teacher spread0.360 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Laboratory MedicineSame topicParathyroid Disorders and TreatmentsFrench-language works237,207