MétaCan
Menu
Back to cohort
Record W4409023827 · doi:10.1093/jbcr/iraf019.158

529 Clinical Performance of Synthetic Dermal Skin Substitute in 77 Patients

2025· article· en· W4409023827 on OpenAlexaboutno aff
Sigrid A Blome-Eberwein, Laetitia Roegner, Kurt Glaeser, Hamed Amani, Kyle Shaak

Bibliographic record

VenueJournal of Burn Care & Research · 2025
Typearticle
Languageen
FieldMedicine
TopicSkin Protection and Aging
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineDermatologyIntensive care medicine

Abstract

fetched live from OpenAlex

Abstract Introduction Dermal skin substitutes are intended to compensate for the absence of dermal elements in traumatic wounds including severe burn injuries and are increasingly utilized in American Burn Centers. However, publications on the clinical performance of synthetic skin substitutes remain limited to small series or case reports. Furthermore, scarring outcomes after the two-step process of applying synthetic skin substitutes and split-thickness skin grafts (STSG) have hardly been studied at all. This IRB approved study was designed as a retrospective detailed assessment of the performance of synthetic skin substitutes, scarring outcomes, and their overall effectiveness in our center. Methods This study included all patients who underwent the two-stage wound closure procedure between 9/1/2017 and 2/28/2024. Patient electronic records were reviewed retrospectively. The evaluated data points included complications, as determined by infection and failure rates, the time delay between the application of the synthetic skin substitute and STSG, LOS after skin substitute placement, Vancouver Scar Scale (VSS) assessments, Patient and Observer Scar Assessment Scale (POSAS) questionnaires, and scar shrinkage measurements during follow up visits. All data were entered into RedCap® for analysis. Results The study included 77 patients and a total of 124 dermal synthetic skin substitute applications (122 synthetic biodegradable, 2 collagen based). All applications were analyzed, and the infection rate overall was 8.8%. The failure rate was found to be 3.2%. The time delay between the application date of the skin substitute and STSG averaged 28 days, to wound closure 35 days. The LOS after skin substitute averaged 45 days, after wound closure 10 days. Data on postoperative dressings (Silver 54.8%, VAC 38.7%), STSG thickness (0.0085), exposed structures in the wound etc. were also collected. 3-12 months post hospital discharge, the mean Vancouver scar scale rating was 8.39 out of 15, the mean Patient and Observer Scar Assessment Scale rating was 36.86 out of 60, and the median scar shrinkage was 2.89% of the initial wound size. Conclusions The usage of synthetic dermal skin substitute allows for a safe, reliable two-stage burn and wound closure. This burn/wound treatment exhibited minimal complications and long-term durability with acceptable scar formation and shrinkage. Applicability of Research to Practice Immediate Funding for the Study Institutional Burn research fund

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.161
Threshold uncertainty score0.505

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.058
GPT teacher head0.448
Teacher spread0.390 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Burn Care & ResearchSame topicSkin Protection and AgingFrench-language works237,207