MétaCan
Menu
← Back to cohort
Record W4409040575 · doi:10.1021/acs.analchem.5c00429

Examining Instrumental Factors Influencing the Performance of Data-Independent Acquisition Methods in Hydrogen/Deuterium Exchange Mass Spectrometry

2025· article· en· W4409040575 on OpenAlexafffund
František Filandr, Morgan Hepburn, Vladimir Sarpe, D. Alex Crowder, Maryam Hassannia, Stephen J. Coales, Yuqi Shi, Rosa Viner, Martín A. Rossotti, Joey Sheff, Jamshid Tanha, David C. Schriemer

Bibliographic record

VenueAnalytical Chemistry · 2025
Typearticle
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsUniversity of OttawaNational Research Council CanadaUniversity of Calgary
FundersNational Cancer InstituteNatural Sciences and Engineering Research Council of Canada
KeywordsChemistryMass spectrometryDeuteriumHydrogen–deuterium exchangeHydrogenChromatographyAnalytical Chemistry (journal)Organic chemistryNuclear physics

Abstract

fetched live from OpenAlex

Hydrogen/deuterium exchange mass spectrometry (HX-MS) is a method used to study solution-phase protein structure and dynamics. Despite its many applications, HX-MS is limited in throughput because manual data analysis is still the norm. We previously developed HX-MS 2 technology to add a second dimension of deuteration data and promote automated data processing. Data-independent acquisition (DIA) techniques enable this approach, but we require optimized methods for best performance. Using an Orbitrap Eclipse for illustration, we show that ion optics and collision energy settings typical of a proteomics DIA experiment generate maximal peptide retrieval from the DIA library. As few as three MS 2 sequence ions are sufficient to generate a deuteration measurement with a precision that exceeds what is possible in traditional HX-MS. DIA window sizes are based on the chromatographic resolution of the method. An inter-scan window offset method is the recommended default configuration for most HX-DIA applications but an intra-scan overlap method can be tuned for highest performance and is recommended when maximum peptide retrieval is desired. We demonstrate the robustness of one HX-MS 2 configuration (consisting of Trajan HDX automation technology, an Orbitrap Eclipse mass spectrometer and AutoHX software) on an extensive time-course analysis of phosphorylase B and an epitope analysis of single-domain antibodies (V H Hs, nanobodies) specific to the receptor binding domain of SARS-CoV-2 spike protein.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.009
metaresearch head score (Gemma)0.025
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.009
Threshold uncertainty score0.050

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0090.025
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.038
GPT teacher head0.338
Teacher spread0.300 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueAnalytical Chemistry→Same topicMass Spectrometry Techniques and Applications→French-language works237,207→