MétaCan
Menu
Back to cohort
Record W4409069238 · doi:10.1002/mp.17800

Dosimetric impact of positional uncertainties and a robust optimization approach for rectal intensity‐modulated brachytherapy

2025· article· en· W4409069238 on OpenAlexafffund
Björn Morén, A. Thibodeau-Antonacci, Jonathan Kalinowski, Shirin A. Enger

Bibliographic record

VenueMedical Physics · 2025
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsJewish General HospitalMcGill University
FundersVetenskapsrådetAlliance de recherche numérique du CanadaVINNOVANatural Sciences and Engineering Research Council of CanadaCanada Research Chairs
KeywordsBrachytherapyMonte Carlo methodDosimetryIntensity (physics)Nuclear medicineShieldsRadiation treatment planningMedicineRadiation therapyElectromagnetic shieldingPhysicsMathematicsOpticsSurgeryStatistics

Abstract

fetched live from OpenAlex

Abstract Background Intensity‐modulated brachytherapy (IMBT) employs rotating high‐Z shields during treatment to decrease radiation in certain directions and conform the dose distribution to the target volume. Prototypes for dynamic IMBT have been proposed for prostate, cervical, and rectal cancer. Purpose We considered two shielded applicators for IMBT rectal cancer treatment and investigated how rotational uncertainties in the shield angle and translational uncertainties in the source position affect plan evaluation criteria. Methods The effect of rotational errors of , and , and translational errors of 1, 2 and 3 mm on evaluation criteria were investigated for shields with and emission windows. Further, a robust optimization approach based on quadratic penalties that includes scenarios with errors was proposed. The extent to which dosimetric effects of positional errors can be mitigated with this model was evaluated compared to a quadratic penalty model without scenarios with errors. A retrospective rectal cancer data set of ten patients was included in this study. Treatment planning was performed using the Monte Carlo‐based treatment planning system, RapidBrachyMCTPS. Results For the largest investigated rotational error of , the clinical target volume remained, on average, within of the result without error, while the contralateral healthy rectal wall experienced an increase in the mean , , and of , , and for the shield and of 32%, 9%, and 2% for the shield. For translational errors of mm, there were increases in dosimetric indices for both the superior (sup) and inferior (inf) dose spill regions. Specifically, for the shield, the , , and increased by , , and , respectively, for the sup region, and by , , and , respectively, for the inf region. Similar results were obtained with the shield. Overall, the robust and traditional models had similar results. However, the number of active dwell positions obtained with the robust model was larger, and the longest dwell time was shorter. Conclusions We have quantified the effect of rotational shield and translational source errors of various magnitudes on evaluation criteria for rectal IMBT. The robust optimization approach was generally not able to mitigate positional errors. However, it resulted in more homogeneous dwell times, which can be beneficial in conventional high‐dose‐rate brachytherapy to avoid hot spots around specific dwell positions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.006
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.003
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.291
Teacher spread0.280 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207