MétaCan
Menu
Back to cohort
Record W4409302597 · doi:10.3389/fpubh.2025.1569494

Ventilation approaches and radon control in Canadian houses

2025· article· en· W4409302597 on OpenAlexaffabout
Janet Gaskin, Liang Grace Zhou, Yunyi Li, Patrique Tardif

Bibliographic record

VenueFrontiers in Public Health · 2025
Typearticle
Languageen
FieldHealth Professions
TopicRadioactivity and Radon Measurements
Canadian institutionsNational Research Council Canada
Fundersnot available
KeywordsRadonVentilation (architecture)Control (management)Environmental scienceEnvironmental healthEnvironmental planningComputer scienceMedicineGeographyArtificial intelligenceMeteorology

Abstract

fetched live from OpenAlex

Introduction: Balanced mechanical ventilation with heat (sensible heat only) or energy (sensible and latent heat) recovery has the potential to dilute indoor radon and may be an appropriate first step at reducing moderate indoor radon concentration in a house with mechanical exhaust only. A field study of the effectiveness of heat/energy recovery ventilation systems at reducing moderate indoor radon concentration was conducted in 13 occupied houses and three test houses in Canada. Controlled experiments were also conducted at the test houses to evaluate indoor radon concentration under different depressurization and ventilation scenarios. Methods: In the field study of heat recovery ventilation systems (HRVs) in occupied homes, the indoor radon concentration was measured for different HRV settings within a season to estimate the effectiveness of radon reduction. In the controlled depressurization experiments in the test houses, the change in pressure of the basement relative to the subslab and of the basement, main floor and second floor relative to outdoors was evaluated for a range of mechanical exhaust ventilation scenarios. Results: . The median (25th-75th percentiles) effectiveness of radon reduction was 39% (29-50) for continuous HRV operation at high fan speed in the 12 field study houses where it was connected directly to the forced air furnace heating systems. In the test houses, the sustained operation of mechanical exhaust ventilation devices, however, increased the depressurization and the indoor radon concentration, and the indoor radon concentrations observed at the depressurization of -5 Pa were higher than those observed at -10 and -20 Pa. Conclusion: Balanced mechanical ventilation with heat recovery was shown to be an effective radon control strategy in a field study of occupied houses with a moderate initial indoor radon concentration. Improving the energy efficiency of the existing housing stock is a priority in many countries, and including balanced mechanical ventilation systems may be an effective radon control option when conducting energy retrofits in existing houses.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.336
Threshold uncertainty score0.839

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.122
GPT teacher head0.368
Teacher spread0.246 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueFrontiers in Public HealthSame topicRadioactivity and Radon MeasurementsFrench-language works237,207