Implications of Solar Facilities on Adjacent Pipeline Infrastructure – Commissioning and Monitoring
Bibliographic record
Abstract
Abstract As oil and gas operators ramp up their efforts to reduce their carbon footprint, more and more renewable energy projects will be constructed adjacent to pipeline infrastructure and facilities. As part of this effort, a major North American pipeline Operator, has initiated a program to install numerous solar farms at Pump and Compressor Stations over the next few years. These solar facilities often involve the installation of thousands of bare or galvanized steel piles, which could compromise the corrosion protection of the Operator’s assets. Additionally, the solar facility could potentially introduce AC and DC interference risks, and itself be subjected to interference from existing cathodic protection (CP) systems. This paper focuses on the findings during commissioning of the solar facilities and ongoing CP system monitoring and is a follow-up to AMPP Paper C2023-190901 which focused on the design considerations.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.003 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.001 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.003 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".