MétaCan
Menu
Back to cohort
Record W4409737710 · doi:10.1007/s10334-025-01245-3

Rethinking MRI as a measurement device through modular and portable pipelines

2025· review· en· W4409737710 on OpenAlexaff
Agâh Karakuzu, Nadia Blostein, Alex Valcourt Caron, Arnaud Boré, François Rheault, Maxime Descoteaux, Nikola Stikov

Bibliographic record

VenueMagnetic Resonance Materials in Physics Biology and Medicine · 2025
Typereview
Languageen
FieldMedicine
TopicRadiomics and Machine Learning in Medical Imaging
Canadian institutionsUniversité de SherbrookeUniversité de MontréalPolytechnique MontréalMontreal Heart Institute
FundersTamkeenUniversity College CorkIrish Research eLibraryNew York University Abu Dhabi
KeywordsWorkflowComputer scienceBenchmarkingPipeline (software)Modular designSoftware portabilitySoftware engineeringDebuggingModularity (biology)SPARK (programming language)TerminologyData scienceSystems engineeringEngineering

Abstract

fetched live from OpenAlex

The premise of MRI as a reliable measurement device is limited by proprietary barriers and inconsistent implementations, which prevent the establishment of measurement uncertainties. As a result, biomedical studies that rely on these methods are plagued by systematic variance, undermining the perceived promise of quantitative imaging biomarkers (QIBs) and hindering their clinical translation. This review explores the added value of open-source measurement pipelines in minimizing variability sources that would otherwise remain unknown. First, we introduce a tiered benchmarking framework (from black-box to glass-box) that exposes how opacity at different workflow stages propagates measurement uncertainty. Second, we provide a concise glossary to promote consistent terminology for strategies that enhance reproducibility before acquisition or enable valid post-hoc pooling of QIBs. Building on this foundation, we present two illustrative measurement workflows that decouple workflow logic from the orchestration of computational processes in an MRI measurement pipeline, rooted in the core principles of modularity and portability. Designed as accessible entry points for implementation, these examples serve as practical guides, helping users adapt the frameworks to their specific needs and facilitating collaboration. Through critical evaluation of existing approaches, we discuss how standardized workflows can help identify outstanding challenges in translating glass-box frameworks into clinical scanner environments. Ultimately, achieving this goal will require coordinated efforts from QIB developers, regulators, industry partners, and clinicians alike.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.019
metaresearch head score (Gemma)0.015
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.019
Threshold uncertainty score0.098

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0190.015
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0040.003
Science and technology studies0.0000.003
Scholarly communication0.0050.008
Open science0.0030.003
Research integrity0.0020.005
Insufficient payload (model declined to judge)0.0030.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.044
GPT teacher head0.365
Teacher spread0.321 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance Materials in Physics Biology and MedicineSame topicRadiomics and Machine Learning in Medical ImagingFrench-language works237,207