MétaCan
Menu
Back to cohort
Record W4409887832 · doi:10.3390/pr13051349

Optimizing Hydrogen Liquefaction Efficiency Through Waste Heat Recovery: A Comparative Study of Three Process Configurations

2025· article· en· W4409887832 on OpenAlexafffund
Seyed Masoud Banijamali, Adrian Ilinca, Ali Alizadeh Afrouzi, Daniel R. Rousse

Bibliographic record

VenueProcesses · 2025
Typearticle
Languageen
FieldEngineering
TopicThermodynamic and Exergetic Analyses of Power and Cooling Systems
Canadian institutionsÉcole de Technologie Supérieure
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsProcess engineeringExergy efficiencyWaste heatAbsorption refrigeratorExergyEfficient energy useLiquefactionWaste heat recovery unitEnvironmental scienceRefrigerationHeat recovery ventilationWaste managementDegree RankineEngineeringHeat exchangerMechanical engineering

Abstract

fetched live from OpenAlex

Hydrogen (H2) liquefaction is an energy-intensive process, and improving its efficiency is critical for large-scale deployment in H2 infrastructure. Industrial waste heat recovery contributes to energy savings and environmental improvements in liquid H2 processes. This study proposes a comparative framework for industrial waste heat recovery in H2 liquefaction systems by examining three recovery cycles, including an ammonia–water absorption refrigeration (ABR) unit, a diffusion absorption refrigeration (DAR) process, and a combined organic Rankine/Kalina plant. All scenarios incorporate 2 MW of industrial waste heat to improve precooling and reduce the external power demand. The simulations were conducted using Aspen HYSYS (V10) in combination with an m-file code in MATLAB (R2022b) programming to model each configuration under consistent operating conditions. Detailed energy and exergy analyses are performed to assess performance. Among the three scenarios, the ORC/Kalina-based system achieves the lowest specific power consumption (4.306 kWh/kg LH2) and the highest exergy efficiency in the precooling unit (70.84%), making it the most energy-efficient solution. Although the DAR-based system shows slightly lower performance, the ABR-based system achieves the highest exergy efficiency of 52.47%, despite its reduced energy efficiency. By comparing three innovative configurations using the same industrial waste heat input, this work provides a valuable tool for selecting the most suitable design based on either energy performance or thermodynamic efficiency. The proposed methodology can serve as a foundation for future system optimization and scale-up.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.217
Threshold uncertainty score0.574

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.278
Teacher spread0.259 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueProcessesSame topicThermodynamic and Exergetic Analyses of Power and Cooling SystemsFrench-language works237,207