MétaCan
Menu
Back to cohort
Record W4410037652 · doi:10.1002/mrm.30543

Impact of through‐slice gradient optimization for dynamic slice‐wise shimming in the cervico‐thoracic spinal cord

2025· article· en· W4410037652 on OpenAlexafffund
Arnaud Bréhéret, Alexandre D’Astous, Yixin Ma, Jason Stockmann, Julien Cohen‐Adad

Bibliographic record

VenueMagnetic Resonance in Medicine · 2025
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsUniversité de MontréalMila - Quebec Artificial Intelligence InstituteCentre Hospitalier Universitaire Sainte-JustinePolytechnique Montréal
FundersNational Institute of Biomedical Imaging and BioengineeringFonds de Recherche du Québec - SantéCanada Research ChairsCanada First Research Excellence FundNatural Sciences and Engineering Research Council of CanadaCanada Foundation for Innovation
KeywordsShim (computing)Gradient echoSpinal cordImage qualityImaging phantomGhostingSIGNAL (programming language)Computer scienceBiomedical engineeringPhysicsNuclear medicineAcousticsMagnetic resonance imagingArtificial intelligenceRadiologyMedicineOpticsImage (mathematics)

Abstract

fetched live from OpenAlex

Abstract Purpose This study investigates the effectiveness of through‐slice gradient optimization in dynamic slice‐wise B0 shimming of the cervico‐thoracic spinal cord to enhance signal recovery in gradient‐echo (GRE) EPI sequences commonly used in functional MRI studies. Methods Six volunteers underwent MRI acquisitions with dynamic shim updating (DSU) using a custom‐built 15‐channel AC/DC coil at 3 T. A magnetization‐prepared rapid gradient echo was acquired to segment the spine and to provide a clear image of the anatomical region of interest in the figures. GRE B0 field maps were used to measure field homogeneity before and after shimming; the pre‐shimming field map was used for optimization. Shimmed fields were dynamically applied to GRE–echo planar imaging acquisitions simulating functional MRI acquisitions under two shimming conditions: DSU with and without through‐slice gradient consideration. Results DSU with through‐slice gradient optimization increased the temporal signal‐to‐noise ratio at the T2 vertebral level by 201% compared with volume‐wise shim and by 28% compared with DSU without through‐slice. The residual geometric distortions were similar between DSU with and without through‐slice gradient optimization. A high signal loss penalty parameter was effective in simulations for reducing through‐slice gradient‐induced signal loss but led to instability and reduced image quality in actual acquisitions due to excessive in‐plane B0 inhomogeneities. Conclusion Introducing a carefully balanced through‐slice gradient parameter in slice‐wise shimming substantially improves signal recovery in axial GRE images of the spinal cord, without compromising in‐plane homogeneity. This effective approach can advance spinal cord functional MRI applications at high field strengths.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.428
Teacher spread0.398 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207