Anti-thermal quenching in NdIII molecular near-infrared thermometers operating at physiological temperatures
Bibliographic record
Abstract
Examples of molecular complexes acting as thermometers operating at room temperature in near infrared region are scarce, therefore this work showcases the anti-thermal quenching effect on neodymium(III) molecular thermometers working in biological windows within the physiological temperature range. A mononuclear complex, [Nd(L)(NO3)3] (1Nd), where L is a macrocyclic ligand, was synthesized and used as a precursor to develop two novel species: a dinuclear, [(Nd(L)(NO3))2(µ-BDC)](NO3)2·H2O (2Nd), linked by 1,4-benzenedicarboxylate (BDC), and a hexameric, [(Nd(L))(µ-BTC)(H2O)]6·35H2O (6Nd), linked with 1,3,5-benzenetricarboxylate (BTC). Thermometric properties were studied in the physiological temperature range (292-332 K), utilizing 804 nm laser excitation (first biological window) and monitoring emissions in the second biological window (908, 1065, and 1340 nm) associated with the 4F3/2 → 4I9/2, 4I11/2, 4I13/2 transitions, respectively. Among the complexes, the hexamer 6Nd exhibited exceptional performance, with Sr of 2.4%K-1 at 293 K, when luminescence intensity ratio (LIR) of two Stark components of the 4F3/2 → 4I11/2 emission was used, positioning it as a high-performance NdIII-based thermometer. All complexes displayed anti-thermal quenching behavior, surpassing the current molecular-based thermometers in the near-infrared region. Theoretical calculations using complete active space self consistent field (CASSCF) and Boltzmann population models between Kramers doublets of the 4F3/2 level were performed to rationalize the anti-thermal behavior.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".