MétaCan
Menu
Back to cohort
Record W4410183396 · doi:10.3389/fmed.2025.1519768

Artificial intelligence versus manual screening for the detection of diabetic retinopathy: a comparative systematic review and meta-analysis

2025· review· en· W4410183396 on OpenAlexaboutno aff
Hasan Nawaz Tahir, Naseer Ullah, Mursala Tahir, Inbaraj Susai Domnic, Ramaprabha Prabhakar, Semmal Syed Meerasa, Ahmed Ibrahim AbdElneam, Shahnawaz Tahir, Yousaf Ali

Bibliographic record

VenueFrontiers in Medicine · 2025
Typereview
Languageen
FieldMedicine
TopicRetinal Imaging and Analysis
Canadian institutionsnot available
FundersShaqra University
KeywordsMeta-analysisDiabetic retinopathyMedicineArtificial intelligenceComputer scienceOptometryInternal medicineDiabetes mellitusEndocrinology

Abstract

fetched live from OpenAlex

Background: Diabetic retinopathy is one of the leading causes of blindness globally, among individuals with diabetes mellitus. Early detection through screening can help in preventing disease progression. In recent advancements artificial Intelligence assisted screening has emerged as an alternative to traditional manual screening methods. This diagnostic test accuracy (DTA) review aims to compare the sensitivity and specificity of AI versus manual screening for detecting diabetic retinopathy, focusing on both dilated and un-dilated eyes. Methods: A systematic review and meta-analysis were conducted for comparison of AI vs. manual screening of diabetic retinopathy using 25 observational (cross sectional, validation and cohort) studies with total images of 613,690 used for screening published between January 2015 and December 2024. Outcomes of the study was sensitivity, and specificity. Risk of bias was assessed using the QUADAS-2 tool for validation studies, the AXIS tool for cross-sectional studies, and the Newcastle-Ottawa Scale for cohort studies. Results: The results of this meta-analysis showed that for un-dilated eyes, AI screening showed pooled sensitivity of 0.90 [95% CI: 0.85-0.94] and pooled specificity of 0.94 [95% CI: 0.91-0.96] while manual screening shows pooled sensitivity of 0.79 [95% CI: 0.60-0.91] and pooled specificity of 0.99 [95% CI: 0.98-0.99]. For dilated eyes the pooled sensitivity of AI screening is 0.95 [95% CI: 0.91-0.97] and pooled specificity is 0.87 [95% CI: 0.79-0.92], while manual screening sensitivity is 0.90 [95% CI: 0.87-0.92] and specificity is 0.99 [95% CI: 0.99-1.00]. These data show comparable sensitivities and specificities of AI and manual screening, with AI performing better in sensitivity. Conclusion: AI-assisted screening for diabetic retinopathy shows comparable sensitivity and specificity compared to manual screening. These results suggest that AI can be a reliable alternative in clinical settings, with increased early detection rates and reducing the burden on ophthalmologists. Further research is needed to validate these findings. Systematic review registration: https://www.crd.york.ac.uk/PROSPERO/home, CRD42024596611.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.771
Threshold uncertainty score0.850

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0120.002
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.176
GPT teacher head0.430
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations13
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueFrontiers in MedicineSame topicRetinal Imaging and AnalysisFrench-language works237,207