Electrode Design for Internal Electric Field Delivery to Brain Tumors: Considering Electrical Power and Dynamic Field Shaping

2025· article· en· W4410204506 on OpenAlexafffund
Erin Iredale, Lucas G. Westerink, Abdulla Elsaleh, Vera Luo, Susanne Schmid, Matthew O. Hebb, Terry M. Peters, Eugene Wong

Bibliographic record

VenueIEEE Transactions on Biomedical Engineering · 2025
Typearticle
Languageen
FieldNeuroscience
TopicNeuroscience and Neural Engineering
Canadian institutionsWestern University
FundersCanada Foundation for InnovationCancer Research Society
KeywordsField (mathematics)Electrical engineeringElectrodePower (physics)Electric fieldEngineeringComputer scienceElectronic engineeringPhysics

Abstract

fetched live from OpenAlex

OBJECTIVE: Brain cancer treatment using low intensity electrotherapy techniques is gaining interest. Localized electric field delivery via an implanted array of electrodes, termed Intratumoral Modulation Therapy (IMT), was found efficacious against brain cancers preclinically. With prior IMT studies supporting the transition towards patient application, we consider optimizing the design of electrodes, such that power consumption is minimized while retaining tumor field coverage and field shaping capability. METHODS: Cylindrical multi-contact electrodes were modelled with variable radius, spacing between contacts and contact length, and applied to spherical tumors ranging from 20-40 mm in diameter. Stimulation programming was optimized and the overall power analyzed for each design such that target coverage was maintained. To investigate the field shaping potential, designs were further optimized on 11 glioma patient MR images with irregular shaped tumors. RESULTS: The IMT electrode parameters found to minimize power consumption were maximal electrode radius (0.8 mm) and minimal contact spacing (1 mm). Analysis of treatment plans on patient images found 4 mm contact length to minimize complexity (total number of contacts) while maintaining field shaping capability. CONCLUSION: In this study, electrodes were designed specifically for IMT that minimized power consumption while maintaining field coverage and shaping. This design was robust in its applicability to patient samples. SIGNIFICANCE: Due to the complexity of dynamic IMT electric field delivery, the established planning system and the custom IMT hardware designed in this study are necessary precursors to human applications. With this work we are one step closer to treating patients with brain cancer.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.850
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.264
Teacher spread0.247 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Biomedical EngineeringSame topicNeuroscience and Neural EngineeringFrench-language works237,207