MétaCan
Menu
Back to cohort

High-speed x-ray characterizes fracture incidence and bone-implant motion during a fall from standing

2025· article· en· W4410352188 on OpenAlexafffund
Emily K. Bliven, Pierre Guy, Alexander Baker, Anita Fung, Benedikt Helgason, Peter A. Cripton

Bibliographic record

VenueClinical Biomechanics · 2025
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsUniversity of British Columbia
FundersUniversity of British ColumbiaEidgenössische Technische Hochschule ZürichSchweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
KeywordsFracture (geology)ImplantIncidence (geometry)OrthodonticsMedicineMotion (physics)Bone fracturePhysical medicine and rehabilitationMaterials scienceDentistryPhysicsRadiologySurgeryComposite materialOpticsClassical mechanics

Abstract

fetched live from OpenAlex

BACKGROUND: Fall-related traumas like hip fracture are a common yet devastating injury with poor outcomes. Characterizing fracture biomechanics and bone-implant kinematics is essential to increase our understanding of these events to inform treatment and prevention strategies. METHODS: This study developed a bilateral high-speed x-ray methodology for the real-time capture of fracture and kinematic data near the hip during fall impacts. High speed x-ray was applied to capture fall impacts of seven cadaveric pelvis-femur specimens encased in a soft tissue surrogate, using a previously developed method. In these specimens, the intact proximal femur had been prophylactically reinforced with an intramedullary nailing system intended to prevent fragility fractures. The feasibility of extracting 3D kinematic data from x-ray data was investigated. FINDINGS: The HSXR system demonstrated visual clarity and sufficient resolution for capturing skeletal fracture and kinematics. The data in this study revealed fracture and newly-seen deformations of the pelvis, highlighting the ability of the x-ray system to document real-time fracture and kinematic events. Kinematic data in 3D was extracted with sufficient accuracy for one specimen. INTERPRETATION: These results demonstrate the merit of high-speed x-ray for studying periprosthetic fracture, which is of increasing relevance due to increasing populations with orthopedic hardware. Application of this method advances our understanding of impact-related biomechanics and fracture mechanics during a clinically-relevant fall from standing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.768
Threshold uncertainty score0.685

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.311
Teacher spread0.290 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueClinical BiomechanicsSame topicOrthopaedic implants and arthroplastyFrench-language works237,207