MétaCan
Menu
Back to cohort
Record W4410425445 · doi:10.32920/29090009

Monte Carlo calculation of 119Sb microscale absorbed dose using cascaded and averaged Auger electron spectra

2025· preprint· en· W4410425445 on OpenAlexfundno aff
A. V. Zwaniga, Raffi Karshafian, Humza Nusrat, Eric Da Silva, James L Gräfe

Bibliographic record

Venuenot available
Typepreprint
Languageen
FieldMaterials Science
TopicElectron and X-Ray Spectroscopy Techniques
Canadian institutionsnot available
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsMonte Carlo methodMicroscale chemistryElectronSpectral lineAuger electron spectroscopyComputational physicsAugerPhysicsStatistical physicsAtomic physicsNuclear physicsMathematicsStatisticsQuantum mechanics

Abstract

fetched live from OpenAlex

Radionuclides decaying by electron capture or internal transition produce a large number of Auger electrons in a cascade that follows their radioactive decay. A shortlist of the most potent Auger electron-emitters has appeared in the literature including 103mRh, 103Pd, 111In, 119Sb, 123I, 125I, 165Er, and 197Hg. Among them, 119Sb has been identified as the most potent for targeting micrometastases, yielding several tens of Auger electrons per decay with energies from a few eV up to 30 keV. In this paper, we recalculate Auger, Coster-Kronig, and super Coster-Kronig yields and transition probabilities as subshell-normalized relative transition probabilities and develop a new method to create radionuclide sources in TOPAS Monte Carlo, the code for which has been made publicly available. We then apply our method to encode the Auger electron spectra of 119Sb from MIRD RADTABS and EADL into TOPAS and calculate the absorbed dose to water volumes of radius 10 nm up to 10 μm, finding that the averaged MIRD Auger electron spectrum underestimates the absorbed dose by a factor of 20 to 50 on this scale. We show that this result is not isolated to 119Sb and conclude that either the cascaded MIRD or EADL spectrum should be used for accurate microscale dosimetry. We compare with results obtained using the built-in Geant4 Atomic Relaxation for 119Sb in TOPAS and find an unexpected continuum of low-energy electrons but no excess absorbed dose relative to either MIRD or EADL. We show that 119Sb does not produce more absorbed dose in microscale volumes than 103mRh, 103Pd, 111In, 123I, 125I, 165Er, or 197Hg, warranting future microdosimetry calculations of RBE and DNA damage to understand whether 119Sb is the most potent Auger electron-emitter, as claimed in the literature.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.015
Threshold uncertainty score0.029

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.307
Teacher spread0.290 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same topicElectron and X-Ray Spectroscopy TechniquesFrench-language works237,207