MétaCan
Menu
← Back to cohort
Record W4410603332 · doi:10.1136/bmjopen-2024-093938

Random capillary blood glucose in the diagnosis of diabetes: a cross-sectional study in Bangladesh

2025· article· en· W4410603332 on OpenAlexaff
Bishwajit Bhowmik, Tasnima Siddiquee, Sanjida Binte Munir, Tareen Ahmed, Faria Afsana, Md Faruque Pathan, Nazmul Kabir Qureshi, Ahmed Salam Mir, Md. Rafiqul Islam, Md. Sarowar Uddin Milon, Rahat Iqbal Chowdhury, Rie Ozaki, Sumon Rahman Chowdhury, Sanjib Salah Aufi, Shamima Akhtar, Tamanna Afroz, Mohammad Abdus Samad, Hajera Mahtab, Md Robed Amin, Abul Kalam Azad Khan

Bibliographic record

VenueBMJ Open · 2025
Typearticle
Languageen
FieldMedicine
TopicHyperglycemia and glycemic control in critically ill and hospitalized patients
Canadian institutionsCentre for Global Health Research
Fundersnot available
KeywordsMedicineDiabetes mellitusConcordanceGlycated haemoglobinPlasma glucoseInternal medicineCross-sectional studyType 2 diabetesArea under the curveGastroenterologyEndocrinologyPathology

Abstract

fetched live from OpenAlex

OBJECTIVE: To assess the effectiveness of random capillary blood glucose as a diagnostic tool for type 2 diabetes and determine optimal cut-off values for adults in Bangladesh. DESIGN: Cross-sectional diagnostic accuracy study. SETTING: 16 diabetes centres were selected randomly from all eight administrative divisions of Bangladesh. PARTICIPANTS: A total of 3200 adults aged 18 years and older were recruited using systematic random sampling between May and September 2022. PRIMARY AND SECONDARY OUTCOME MEASURES: The primary outcome was the diagnostic accuracy of random capillary blood glucose compared to fasting plasma glucose, 2-hour plasma glucose after a 75-gram glucose load and glycated haemoglobin. Secondary outcomes included sensitivity, specificity, area under the curve and agreement with the other diagnostic tests. RESULTS: Random capillary blood glucose showed a strong positive correlation and high concordance with fasting plasma glucose, 2-hour plasma glucose and glycated haemoglobin. A cut-off value of ≥8.7 mmol/L demonstrated improved diagnostic performance compared with the currently used cut-off of ≥11.1 mmol/L. This new threshold yielded higher sensitivity, specificity, area under the curve and agreement with other standard diagnostic tests. Notably, hyperglycaemic symptoms were not required for diagnosis. The number needed to screen to identify one case of type 2 diabetes using the ≥8.7 mmol/L cut-off was 2.74, lower than that for fasting plasma glucose (2.86) and random capillary blood glucose ≥11.1 mmol/L (4.68). CONCLUSIONS: Random capillary blood glucose may be an effective and affordable diagnostic tool for type 2 diabetes in resource-limited settings. The proposed cut-off of ≥8.7 mmol/L offers improved diagnostic accuracy and reflects the population's glucose distribution pattern.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.013
Threshold uncertainty score0.026

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.006
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.045
GPT teacher head0.393
Teacher spread0.347 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueBMJ Open→Same topicHyperglycemia and glycemic control in critically ill and hospitalized patients→French-language works237,207→