A 3D-printed circularly polarized cavity-based slotted waveguide antenna for kidney cancer detection application
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
This paper presents a novel circularly polarized (CP) slot antenna based on a waveguide cavity resonator for kidney cancer detection applications. The cavity is coupled to the input port via a capacitive iris, ensuring strong coupling and improved impedance matching compared to conventional waveguide slot antennas. An L-shaped radiating slot, formed by two orthogonal linearly polarized (LP) slots, is etched into the broad wall of the cavity to generate CP radiation. The axial ratio bandwidth (ARBW) is enhanced by optimizing the slot dimensions. To validate the predicted results, a 3D-printed prototype was fabricated and tested. The measured 10-dB fractional bandwidth (FBW) is 7.4 % at the center frequency ( f 0 ) f 0 = 10 GHz, while the 3-dB ARBW and peak gain are 7.0 % and 7.5 dBic, respectively. The detection capability of the proposed antenna is evaluated in a modeled measurement system, revealing a calculated sensitivity of 0.175 GHz/RIU at f 0 =10 GHz. Furthermore, the antenna exhibits a resonance frequency shift of 0.21 GHz when tested with renal cancer cells, distinguishing them from normal cells. These findings demonstrate that the proposed antenna effectively distinguishes between normal and cancerous kidney cells, making its potential as a good candidate for kidney cancer detection.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it