MétaCan
Menu
Back to cohort
Record W4410722148 · doi:10.1002/mp.17872

Reference datasets for commissioning of model‐based dose calculation algorithms for electronic brachytherapy

2025· article· en· W4410722148 on OpenAlexafffund
Iymad Mansour, Christian Valdes‐Cortez, David Santiago Ayala Alvarez, Francisco Berumen, Gaël Ndoutoume‐Paquet, Peter Watson, Jan Seuntjens, Facundo Ballester, Ernesto Mainegra‐Hing, Rowan M. Thomson, Luc Beaulieu, J. Vijande

Bibliographic record

VenueMedical Physics · 2025
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsNational Research Council CanadaUniversité LavalPrincess Margaret Cancer CentreCarleton UniversityUniversity Health NetworkUniversity of TorontoMcGill University
FundersEuropean Regional Development FundGeneralitat ValencianaAgencia Estatal de InvestigaciónJunta de Castilla y LeónCarl Zeiss Meditec AGCanadian Institutes of Health ResearchNatural Sciences and Engineering Research Council of CanadaEuropean Commission
KeywordsImaging phantomBrachytherapyComputer scienceAlgorithmRadiation treatment planningRadianceDosimetryCalibrationMonte Carlo methodMedical physicsSoftwareNuclear medicineMathematicsPhysicsRadiation therapyRadiologyMedicineOpticsStatistics

Abstract

fetched live from OpenAlex

PURPOSE: This work provides the first two clinical test cases for commissioning electronic brachytherapy (eBT) model-based dose calculation algorithms (MBDCAs) for skin irradiation using surface applicators. ACQUISITION AND VALIDATION METHODS: The test cases utilize the INTRABEAM 30 mm surface applicator. Test Case I: water phantom is used to evaluate the algorithm's performance in a uniform medium consisting of a voxelized water cube surrounded by air. Test Case II: Surface eBT represents a heterogeneous medium with four distinct layers: skin tissue, adipose tissue, cortical bone, and soft tissue. Treatment plans for both cases were created and exported into the Radiance treatment planning system (TPS). Dose-to-medium calculations were then performed using this Monte Carlo (MC)-based TPS and compared with MC simulations conducted independently by three different groups using two codes: EGSnrc and PENELOPE. The results agreed within expected Type A and B statistical uncertainties. DATA FORMAT AND USAGE NOTES: The dataset is available online at https://doi.org/10.52519/00005. A proprietary file designed for use within Radiance containing CT images and the treatment plan for both test cases, the LINAC modeling, and the CT calibration are included, as well as reference MC and TPS dose data in RTdose format and all files required to run the MC simulations. POTENTIAL APPLICATIONS: This dataset serves as a valuable resource for commissioning eBT MBDCAs and lays the groundwork for developing clinical test cases for other eBT systems. It is also a helpful educational tool for exploring various eBT devices and their advantages and drawbacks. Furthermore, brachytherapy researchers seeking a benchmark for dosimetric calculations in the low-energy domain will find this dataset indispensable.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.015
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Dataset · Consensus signal: Dataset
Teacher disagreement score0.028
Threshold uncertainty score0.093

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.015
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.005
Science and technology studies0.0010.001
Scholarly communication0.0020.002
Open science0.0040.002
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0280.020

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.028
GPT teacher head0.371
Teacher spread0.343 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreDataset

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207