Abstract

fetched live from OpenAlex

Background Despite its potential to improve the assessment of cardiovascular diseases, 4D Flow CMR is hampered by long scan times. 4D Flow CMR is conventionally acquired with three motion encodings and one reference encoding, as the 3-dimensional velocity data are obtained by subtracting the phase of the reference from the phase of the motion encodings. In this study, we aim to use deep learning to predict the reference encoding from the three motion encodings for cardiovascular 4D Flow. Methods A U-Net was trained with adversarial learning (U-Net ADV ) and with a velocity frequency-weighted loss function (U-Net VEL ) to predict the reference encoding from the three motion encodings obtained with a non-symmetric velocity-encoding scheme. Whole-heart 4D Flow datasets from 126 patients with different types of cardiomyopathies were retrospectively included. The models were trained on 113 patients with a 5-fold cross-validation, and tested on 13 patients. Flow volumes in the aorta and pulmonary artery, mean and maximum velocity, total and maximum turbulent kinetic energy at peak systole in the cardiac chambers and main vessels were assessed. Results 3-dimensional velocity data reconstructed with the reference encoding predicted by deep learning agreed well with the velocities obtained with the reference encoding acquired at the scanner for both models. U-Net ADV performed more consistently throughout the cardiac cycle and across the test subjects, while U-Net VEL performed better for systolic velocities. Comprehensively, the largest error for flow volumes, maximum and mean velocities was -6.031% for maximum velocities in the right ventricle for the U-Net ADV , and -6.92% for mean velocities in the right ventricle for U-Net VEL . For total turbulent kinetic energy, the highest errors were in the left ventricle (-77.17%) for the U-Net ADV , and in the right ventricle (24.96%) for the U-Net VEL , while for maximum turbulent kinetic energy were in the pulmonary artery for both models, with a value of -15.5% for U-Net ADV and 15.38% for the U-Net VEL . Conclusion Deep learning-enabled referenceless 4D Flow CMR permits velocities and flow volumes quantification comparable to conventional 4D Flow. Omitting the reference encoding reduces the amount of acquired data by 25%, thus allowing shorter scan times or improved resolution, which is valuable for utilization in the clinical routine.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: none
Teacher disagreement score0.990
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.002
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.244
Teacher spread0.235 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designOther design
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cardiovascular Magnetic ResonanceSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207