MétaCan
Menu
Back to cohort
Record W4411135751 · doi:10.1093/rheumatology/keaf323

Automated detection of spinal bone marrow oedema in axial spondyloarthritis: training and validation using two large phase 3 trial datasets

2025· article· en· W4411135751 on OpenAlexaff
Amir Jamaludin, Rhydian Windsor, Sarim Ather, Timor Kadir, Andrew Zisserman, Jürgen Braun, Lianne S. Gensler, Mikkel Østergaard, Denis Poddubnyy, Thibaud Coroller, Brian Porter, Gregory Ligozio, Aimee Readie, Pedro Machado

Bibliographic record

VenueLara D. Veeken · 2025
Typearticle
Languageen
FieldEngineering
TopicMedical Imaging and Analysis
Canadian institutionsUniversity of TorontoUniversity Health Network
FundersMedacCelgeneGilead SciencesSanofiRegeneron PharmaceuticalsNovartisAmgenPfizerEli Lilly and Company
KeywordsAxial spondyloarthritisMedicineBone marrowPhysical therapyRadiologyMagnetic resonance imagingPathology

Abstract

fetched live from OpenAlex

OBJECTIVE: To evaluate the performance of machine learning (ML) models for the automated scoring of spinal MRI bone marrow oedema (BMO) in patients with axial spondyloarthritis (axSpA) and compare them with expert scoring. METHODS: ML algorithms using SpineNet software were trained and validated on 3483 spinal MRIs from 686 axSpA patients across two clinical trial datasets. The scoring pipeline involved (i) detection and labelling of vertebral bodies and (ii) classification of vertebral units for the presence or absence of BMO. Two models were tested: Model 1, without manual segmentation, and Model 2, incorporating an intermediate manual segmentation step. Model outputs were compared with those of human experts using kappa statistics, balanced accuracy, sensitivity, specificity and AUC. RESULTS: Both models performed comparably to expert readers, regarding presence vs absence of BMO. Model 1 outperformed Model 2, with an AUC of 0.94 (vs 0.88), accuracy of 75.8% (vs 70.5%) and kappa of 0.50 (vs 0.31) using absolute reader consensus scoring as the external reference; this performance was similar to the expert inter-reader accuracy of 76.8% and kappa of 0.47 in a radiographic axSpA dataset. In a non-radiographic axSpA dataset, Model 1 achieved an AUC of 0.97 (vs 0.91 for Model 2), accuracy of 74.6% (vs 70%) and kappa of 0.52 (vs 0.27), comparable to the expert inter-reader accuracy of 74.2% and kappa of 0.46. CONCLUSION: ML software shows potential for automated MRI BMO assessment in axSpA, offering benefits such as improved consistency, reduced labour costs and minimized inter- and intra-reader variability. TRIAL REGISTRATION: Clinicaltrials.gov, http://clinicaltrials.gov, MEASURE 1 study (NCT01358175); PREVENT study (NCT02696031).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.028
metaresearch head score (Gemma)0.029
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.028
Threshold uncertainty score0.149

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0280.029
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0020.002
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0020.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.022
GPT teacher head0.316
Teacher spread0.294 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueLara D. VeekenSame topicMedical Imaging and AnalysisFrench-language works237,207