Determination of the Intrinsic Rates of Heterogeneous Hydrogen Peroxide Decomposition of Selected Materials in Acidic Electrolytes Using a Selenium-Modified Pt Ring of a Rotating Ring-Disk Electrode
Bibliographic record
Abstract
A rotating ring-disk electrode, RRDE, method is herein described that employs a Se-modified Pt ring electrode to measure the rates of oxygen generation, r O 2, d i s k derived from the heterogeneous hydrogen peroxide decomposition, het-HPD, on the surface of selected disk materials under open circuit, OC, conditions. This technique was inspired by the earlier work of Shigehara and Anson ( J. Phys. Chem. 1982, 86, 2776–2783), who used a high area carbon paste ring electrode modified by an adsorbed layer of a rather unique Co macrocycle to accomplish the same goal. As first discovered by Mo et al. in our laboratory ( J. Electrochem. Soc. 2003, 150, E39-E46), a Pt surface bearing 0.83 ML of elemental Se, which we denote herein as Se(0.83)|Pt, catalyzes the oxygen reduction reaction, ORR, in 0.5 M H 2 SO 4, yielding Levich plots, i lim vs ω 1/2, where i lim is the diffusion limiting current, and ω is the rotation rate of the electrode, consistent with a strict 2e – process. Such plots, however, displayed a nonzero intercept, signaling complications in the ORR mechanism. As will be shown in this work, this behavior could be accounted for by introducing a first order het-HPD step to the otherwise strict 2e – ORR. Application of this formalism to data collected for a Se(0.83)|Pt disk polarized at a potential of 0.175 V vs RHE, a value well within the range where the ORR was found to proceed under diffusion limited conditions, yielded an estimated average first order rate constant in peroxide for the het-HPD step, k D lim = 2.9 × 10 –4 ± 0.1 cm s –1 . In subsequent experiments, the diffusion limited current flowing through a Se(0.83)|Pt ring of a RRDE polarized at 0.175 V vs RHE, i ring lim, was measured for Pt and Se(0.83)|Pt disks held at open circuit, OC, for selected ω and peroxide concentrations in solution. Numerical correlations between i ring lim and r O 2, d i s k were then established using COMSOL, yielding for Se(0.83)|Pt and Pt in [H 2 O 2 ] B = 1 mM, values of r O 2, d i s k of 0.215 and 0.84 nmol cm –2 s –1, respectively. In stark contrast, a GC disk of a demountable RRDE assembly incorporating a Se(0.83)|Pt ring, displayed no activity for het-HPD at OC, i.e. i ring lim was virtually identical to that found for a Teflon disk under the same experimental conditions. Overall, the method described in this work may be regarded as far simpler and more versatile compared to that proposed by Shigehara and Anson, as it avoids the use of chemicals not available from commercial sources.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".