MétaCan
Menu
Back to cohort

Automatic CNN-based 3D/2D non-rigid registration platform for fast 3D femur reconstruction and clinical 3D measurements from Bi-planar radiographs

2025· article· en· W4411987337 on OpenAlexafffund
Nahid Babazadeh Khameneh, Thierry Cresson, Frédéric Lavoie, Jacques A. de Guise, Carlos Vázquez

Bibliographic record

VenueComputers in Biology and Medicine · 2025
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsCentre Hospitalier de l’Université de MontréalÉcole de Technologie Supérieure
FundersMEDTEQ+Natural Sciences and Engineering Research Council of CanadaMitacs
KeywordsArtificial intelligenceDisplacement (psychology)Mean squared errorRadiographyComputer visionComputer scienceStandard deviationSimilarity (geometry)PlanarDeformation (meteorology)Root mean squareAlgorithmMathematicsMedicineImage (mathematics)GeologyRadiologyPhysicsComputer graphics (images)

Abstract

fetched live from OpenAlex

Purpose This paper presents an automatic 3D/2D non-rigid registration method for fast 3D reconstruction and clinical measurements of the femur. Approach The proposed CNN cascade-based 3D/2D registration platform comprises three major steps to fit a generic 3D femur model into 2D bi-planar EOS® radiographs: 1) Pose estimation ( C N N P o s e ) - a combination of Principal Component Analysis (PCA) and CNN-based 3D/2D similarity registration; 2) 3D shape deformation ( C N N S h a p e ) - a CNN-based 3D displacement estimation of handles followed by Moving Least Square (MLS) shape deformation to extend an as-rigid-as-possible deformation to the entire bone, 3) 3D scale deformation ( C N N S c a l e ) - a CNN-based 3D scale ratio estimation of handles followed by MLS-based model rescaling. Results The accuracy of the method is evaluated in comparison to, first, a clinically proved semi-automatic method on 15 patients, and second, Computerized Tomography CT scans of five new patients. In the first validation, the mean ± standard deviation (STD) of the Root Mean Square of point-to-surface distance (RMS-P2S) error is 0.88 ± 0.29 mm. For the second validation, the mean ± STD of RMS-P2S error is 2.70 ± 0.39 mm. Four clinical measurements of the reconstructed 3D femurs are computed and compared with the first validation set. For each clinical measurement, the Mean Absolute Errors (MAE) is below 1 mm or 1°. Conclusions The presented automatic CNN cascade-based framework efficiently registers the generic 3D femur models into bi-planar radiographs. The CNN-based 3D handles displacement and scale estimation eliminates manual-annotations and user-interventions for MLS deformation while maintaining accuracy and speed. This system is applicable for other bones such as the tibia.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.010
Threshold uncertainty score0.027

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0020.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0080.005

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.042
GPT teacher head0.343
Teacher spread0.301 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes2
Has abstractno

Explore more

Same venueComputers in Biology and MedicineSame topicOrthopaedic implants and arthroplastyFrench-language works237,207