MétaCan
Menu
Back to cohort
Record W4412199521 · doi:10.1007/s43390-025-01146-4

Impact of a novel patient-specific, patient-matched Bezier parametric curve rod platform on proximal junction biomechanics in an in silico thoracolumbar instrumented fusion model

2025· article· en· W4412199521 on OpenAlexaff
Franck Le Navéaux, Bahe Hachem, Sasha Vaziri, Varun Puvanesarajah, Saeed S. Sadrameli, David O. Okonkwo, Thomas J. Buell, Amit Jain, Hamid Hassanzadeh, Craig Forsthoefel, Reginald S. Fayssoux, Zachary J. Tempel, Alekos A. Theologis, Christopher S. Ahuja

Bibliographic record

VenueSpine Deformity · 2025
Typearticle
Languageen
FieldMedicine
TopicScoliosis diagnosis and treatment
Canadian institutionsSpinologics (Canada)
FundersUniversity of San Francisco
KeywordsBézier curveRodSagittal planeBiomechanicsReduction (mathematics)KyphosisMedicineBiomedical engineeringMaterials scienceGeometryMathematicsAnatomySurgeryRadiography

Abstract

fetched live from OpenAlex

PURPOSE: To evaluate the biomechanical performance of a novel Bezier surface-smoothed transition rod, and to compare it to conventional and stepped rods, focusing on correction capability, spinal stabilization, instrumentation and spinal loading related to risk of proximal junctional kyphosis (PJK). METHODS: A spine finite element model with patient-specific 3D spinal geometry (severe sagittal imbalance from thoracolumbar kyphosis) was used. Surgical instrumentation with five rod types was simulated: (1) constant 6.0 mm diameter, (2) stepped 6.0 mm-5.0 mm diameter, (3) Bezier 6.0 mm-5.5 mm-5.0 mm diameter, (4) constant 5.5 mm diameter, and (5) Bezier 5.5 mm-5.0 mm-4.75 mm diameter. Gravitational forces and flexion movements were simulated to compare load transfer between the spine and instrumentation. RESULTS: All rod configurations achieved equivalent sagittal correction. Load distribution analysis showed that Bezier rods provided smoother load transitions and better offloading of proximal segments compared to constant diameter rods. The highest moment sustained by the segment adjacent to the instrumentation was observed with the constant 6 mm rod (9N.m), while the Bezier 5.5-5-4.75 mm rod showed the lowest moment (7.5Nm), indicating reduced stress of 16% on the upper adjacent vertebrae. Similarly, the Bezier rods were more effective in offloading pedicle screws up to 45% with respect to the stiffer rod construct, potentially reducing the risk of PJK. CONCLUSIONS: The simulation analysis demonstrates Bezier rods offer promising biomechanical benefits particularly in load distribution and stress reduction at adjacent levels of long thoracolumbar instrumentation. Future efforts will focus on clinical validation and optimization of patient-specific designs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.253
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.002
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.036
GPT teacher head0.324
Teacher spread0.288 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations2
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueSpine DeformitySame topicScoliosis diagnosis and treatmentFrench-language works237,207