Comparative Diagnostic Accuracy of AI-Assisted Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography Versus Structural Magnetic Resonance Imaging in Alzheimer Disease: Systematic Review and Meta-Analysis
Bibliographic record
Abstract
Background: Neuroimaging is crucial in the diagnosis of Alzheimer disease (AD). In recent years, artificial intelligence (AI)-based neuroimaging technology has rapidly developed, providing new methods for accurate diagnosis of AD, but its performance differences still need to be systematically evaluated. Objective: This study aims to conduct a systematic review and meta-analysis comparing the diagnostic performance of AI-assisted fluorine-18 fluorodeoxyglucose positron emission tomography (18F-FDG PET) and structural magnetic resonance imaging (sMRI) for AD. Methods: Databases including Web of Science, PubMed, and Embase were searched from inception to January 2025 to identify original studies that developed or validated AI models for AD diagnosis using 18F-FDG PET or sMRI. Methodological quality was assessed using the TRIPOD-AI (Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis-Artificial Intelligence) checklist. A bivariate mixed-effects model was employed to calculate pooled sensitivity, specificity, and summary receiver operating characteristic curve area (SROC-AUC). Results: A total of 38 studies were included, with 28 moderate-to-high-quality studies analyzed. Pooled SROC-AUC values were 0.94 (95% CI 0.92-0.96) for sMRI and 0.96 (95% CI 0.94-0.98) for 18F-FDG PET, demonstrating statistically significant intermodal differences (P=.02). Subgroup analyses revealed that for machine learning, pooled SROC-AUCs were 0.89 (95% CI 0.86-0.92) for sMRI and 0.95 (95% CI 0.92-0.96) for 18F-FDG PET, while for deep learning, these values were 0.96 (95% CI 0.94-0.97) and 0.97 (95% CI 0.96-0.99), respectively. Meta-regression identified heterogeneity arising from study quality stratification, algorithm types, and validation strategies. Conclusions: Both AI-assisted 18F-FDG PET and sMRI exhibit high diagnostic accuracy in AD, with 18F-FDG PET demonstrating superior overall diagnostic performance compared to sMRI.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.001 |
| Meta-epidemiology (broad) | 0.008 | 0.002 |
| Bibliometrics | 0.001 | 0.003 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".