MétaCan
Menu
Back to cohort
Record W4412505029 · doi:10.2196/76981

Comparative Diagnostic Accuracy of AI-Assisted Fluorine-18 Fluorodeoxyglucose Positron Emission Tomography Versus Structural Magnetic Resonance Imaging in Alzheimer Disease: Systematic Review and Meta-Analysis

2025· review· en· W4412505029 on OpenAlexvenueno aff
Bingbing Wang, Tailiang Zhao, Xiaolu Xiong, Zhijiang Zhuang, Bin Wang, J. Shou

Bibliographic record

VenueJMIR Aging · 2025
Typereview
Languageen
FieldMedicine
TopicDementia and Cognitive Impairment Research
Canadian institutionsnot available
Fundersnot available
KeywordsPreprintMeta-analysisMedicineDiseaseSystematic reviewDiagnostic accuracyMEDLINEPathologyRadiologyComputer scienceBiologyWorld Wide Web

Abstract

fetched live from OpenAlex

Background: Neuroimaging is crucial in the diagnosis of Alzheimer disease (AD). In recent years, artificial intelligence (AI)-based neuroimaging technology has rapidly developed, providing new methods for accurate diagnosis of AD, but its performance differences still need to be systematically evaluated. Objective: This study aims to conduct a systematic review and meta-analysis comparing the diagnostic performance of AI-assisted fluorine-18 fluorodeoxyglucose positron emission tomography (18F-FDG PET) and structural magnetic resonance imaging (sMRI) for AD. Methods: Databases including Web of Science, PubMed, and Embase were searched from inception to January 2025 to identify original studies that developed or validated AI models for AD diagnosis using 18F-FDG PET or sMRI. Methodological quality was assessed using the TRIPOD-AI (Transparent Reporting of a Multivariable Prediction Model for Individual Prognosis or Diagnosis-Artificial Intelligence) checklist. A bivariate mixed-effects model was employed to calculate pooled sensitivity, specificity, and summary receiver operating characteristic curve area (SROC-AUC). Results: A total of 38 studies were included, with 28 moderate-to-high-quality studies analyzed. Pooled SROC-AUC values were 0.94 (95% CI 0.92-0.96) for sMRI and 0.96 (95% CI 0.94-0.98) for 18F-FDG PET, demonstrating statistically significant intermodal differences (P=.02). Subgroup analyses revealed that for machine learning, pooled SROC-AUCs were 0.89 (95% CI 0.86-0.92) for sMRI and 0.95 (95% CI 0.92-0.96) for 18F-FDG PET, while for deep learning, these values were 0.96 (95% CI 0.94-0.97) and 0.97 (95% CI 0.96-0.99), respectively. Meta-regression identified heterogeneity arising from study quality stratification, algorithm types, and validation strategies. Conclusions: Both AI-assisted 18F-FDG PET and sMRI exhibit high diagnostic accuracy in AD, with 18F-FDG PET demonstrating superior overall diagnostic performance compared to sMRI.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.035
metaresearch head score (Gemma)0.083
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Meta-analysis · Consensus signal: Meta-analysis
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.035
Threshold uncertainty score0.185

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0350.083
Meta-epidemiology (narrow)0.0030.002
Meta-epidemiology (broad)0.0220.048
Bibliometrics0.0100.010
Science and technology studies0.0010.001
Scholarly communication0.0040.002
Open science0.0030.002
Research integrity0.0030.002
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.068
GPT teacher head0.429
Teacher spread0.361 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designMeta-analysis
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJMIR AgingSame topicDementia and Cognitive Impairment ResearchFrench-language works237,207