MétaCan
Menu
Back to cohort
Record W4412815123 · doi:10.35882/jeeemi.v7i3.868

Improving Kidney Stone Detection with YOLOV10 and Channel Attention Mechanisms in Medical Imaging

2025· article· en· W4412815123 on OpenAlexaff
Saroj Bala, Kumud Arora, V. Satheeswaran, Sweta Mohan, J. Aruna Deepika, K Sangamithrai, Amala Nirmal Doss

Bibliographic record

VenueJournal of Electronics Electromedical Engineering and Medical Informatics · 2025
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsArtificial Intelligence in Medicine (Canada)
Fundersnot available
KeywordsKidney stonesChannel (broadcasting)MedicineComputer scienceInternal medicineTelecommunications

Abstract

fetched live from OpenAlex

Accurate and timely detection of kidney stones is crucial for effective medical intervention and treatment planning. However, existing detection methods often struggle with challenges related to sensitivity, precision, and the ability to process complex and variable medical images. In this study, an advanced kidney stone detection system is developed using the latest object detection algorithm, You Only Look Once version 10 (YOLOv10), integrated with channel attention mechanisms to enhance model performance. This combination aims to improve detection accuracy by enabling the network to focus more precisely on critical regions in medical images, particularly in Computed Tomography (CT) scans, where kidney stones may appear in varying shapes, sizes, and intensities. The proposed system begins with data augmentation techniques, such as rotation, scaling, and contrast adjustments, to enhance the model’s generalization ability across different image conditions and patient profiles. YOLOv10 was selected due to its lightweight architecture, high detection speed, and enhanced performance in small object detection tasks. To further improve feature extraction, channel attention mechanisms such as Squeeze-and-Excitation (SE) blocks or Efficient Channel Attention (ECA) modules are incorporated. These modules enable the network to selectively focus on the most informative feature channels associated with kidney stone regions, while suppressing irrelevant background information, thereby improving the distinction between stones and surrounding tissues. The model is trained and fine-tuned using a diverse CT scan dataset containing various types and sizes of kidney stones. Evaluation results demonstrate that the proposed model achieves a high detection accuracy of 93.7% with a very low loss of 0.18. It exhibits stability without issues like overfitting, underfitting, or local minima entrapment, making it a highly reliable tool for clinical applications.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.978
Threshold uncertainty score0.796

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.002
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.001
GPT teacher head0.191
Teacher spread0.190 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Electronics Electromedical Engineering and Medical InformaticsSame topicAdvanced X-ray and CT ImagingFrench-language works237,207