MétaCan
Menu
Back to cohort
Record W4412827751 · doi:10.1016/j.jmbbm.2025.107144

Prototype design of porous Ti6Al4V intraosseous implant for use in mandibular reconstruction

2025· article· en· W4412827751 on OpenAlexafffund
K. Hijazi, Haojie Mao, David W. Holdsworth, S. Jeffrey Dixon, Jerrold E. Armstrong, Amin S. Rizkalla

Bibliographic record

VenueJournal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · 2025
Typearticle
Languageen
FieldEngineering
TopicBone Tissue Engineering Materials
Canadian institutionsWestern University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsOsseointegrationImplantMaterials sciencePorosityFinite element methodMandible (arthropod mouthpart)Dental implantStress (linguistics)Stress shieldingTitanium alloyBiomedical engineeringDentistryComposite materialStructural engineeringMedicineEngineeringSurgery

Abstract

fetched live from OpenAlex

The design of patient-specific implants often requires computer simulations for the characterization of mechanical properties before manufacturing. We previously developed numerical models to predict the mechanical properties of porous Ti6Al4V constructs built using laser powder bed fusion (LPBF). Here, we developed a patient-specific porous intraosseous mandibular implant based on the models and techniques described in our previous research. The implant model used a simple cubic porous design with an average unit cell size of 1 mm and strut thicknesses between 350 and 450 μm. Finite element analysis was used to simulate right molar clenching on the mandible with and without the implant, under static and dynamic loading. The simulation showed that the implant would remain intact during right molar clenching and should not cause stress shielding. The fatigue numerical models predicted that the implant would remain functional under cyclic masticatory forces (50-100 N) for a period ranging between 4 and 119 years. Given that, within one year, bone ingrowth and osseointegration are complete, the implant is predicted to remain intact long-term under physiological loading conditions. These findings demonstrate the potential of computational modelling in developing patient-specific designs for porous implants built through LPBF.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.256
Teacher spread0.237 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueJournal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materialsSame topicBone Tissue Engineering MaterialsFrench-language works237,207