Plasma/Serum Electrolyte and Metabolite Testing on Blood Gas Analyzer ABL837, a New Application
Bibliographic record
Abstract
Background: Core laboratory chemistry analyzers typically use plasma and serum samples, while blood gas instruments use whole blood for electrolyte and metabolite tests. Due to high costs to back up the core lab chemistry analyzers, especially in the remote small community hospitals, we have verified the interchangeability of serum/plasma electrolytes and metabolites on blood gas instruments (GEM4000 and Radiometer ABL90) vs. chemistry analyzers. In this study, we sought to extend the investigation to another blood gas device—Radiometer ABL837. Methods: One plasma separator tube and one serum separator tube were drawn from 20 apparently healthy individuals and outpatients and 20 intensive care unit patients. All the samples were run on Roche Cobas8000, and then were run on three Radiometer ABL837 analyzers for sodium (Na+), potassium (K+), chloride (Cl−), glucose, lactate (plasma only), and creatinine parameters. Paired measurements between the ABL837 and Cobas8000 were compared, and their difference were assessed for statistical and clinical significance. Results: ABL837 demonstrated statistical significance (p < 0.05) vs. Cobas8000 on all the plasma and serum parameters. However, no parameter differences were found when comparing the plasma/serum results on ABL837 to those on Cobas8000, indicating that none were clinically significant. ABL837 also demonstrated good–excellent correlations with Cobas8000 on all the parameters. Conclusions: When comparing metabolite and electrolyte values with plasma and serum sample types, the ABL837 blood gas instruments and Cobas 8000 chemistry analyzer are interchangeable. These data proves that ABL837 can be used as a backup for a chemistry analyzer in measuring plasma and serum electrolyte and metabolite concentrations.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.002 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".