MétaCan
Menu
Back to cohort
Record W4412841395 · doi:10.3390/diagnostics15151923

Plasma/Serum Electrolyte and Metabolite Testing on Blood Gas Analyzer ABL837, a New Application

2025· article· en· W4412841395 on OpenAlexaff
Vera Y. Chen, Rachel Fullarton, Yu Chen

Bibliographic record

VenueDiagnostics · 2025
Typearticle
Languageen
FieldMedicine
TopicRenal function and acid-base balance
Canadian institutionsMemorial University of NewfoundlandDalhousie UniversityDr. Everett Chalmers Regional HospitalUniversity of New Brunswick
Fundersnot available
KeywordsElectrolyteSpectrum analyzerChemistryChromatographyMetaboliteGas analyzerCreatinineAutoAnalyzerAnalytical Chemistry (journal)Environmental chemistryBiochemistryPhysicsElectrode

Abstract

fetched live from OpenAlex

Background: Core laboratory chemistry analyzers typically use plasma and serum samples, while blood gas instruments use whole blood for electrolyte and metabolite tests. Due to high costs to back up the core lab chemistry analyzers, especially in the remote small community hospitals, we have verified the interchangeability of serum/plasma electrolytes and metabolites on blood gas instruments (GEM4000 and Radiometer ABL90) vs. chemistry analyzers. In this study, we sought to extend the investigation to another blood gas device—Radiometer ABL837. Methods: One plasma separator tube and one serum separator tube were drawn from 20 apparently healthy individuals and outpatients and 20 intensive care unit patients. All the samples were run on Roche Cobas8000, and then were run on three Radiometer ABL837 analyzers for sodium (Na+), potassium (K+), chloride (Cl−), glucose, lactate (plasma only), and creatinine parameters. Paired measurements between the ABL837 and Cobas8000 were compared, and their difference were assessed for statistical and clinical significance. Results: ABL837 demonstrated statistical significance (p < 0.05) vs. Cobas8000 on all the plasma and serum parameters. However, no parameter differences were found when comparing the plasma/serum results on ABL837 to those on Cobas8000, indicating that none were clinically significant. ABL837 also demonstrated good–excellent correlations with Cobas8000 on all the parameters. Conclusions: When comparing metabolite and electrolyte values with plasma and serum sample types, the ABL837 blood gas instruments and Cobas 8000 chemistry analyzer are interchangeable. These data proves that ABL837 can be used as a backup for a chemistry analyzer in measuring plasma and serum electrolyte and metabolite concentrations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.017

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.003
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0030.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.254
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2025
Admission routes1
Has abstractyes

Explore more

Same venueDiagnosticsSame topicRenal function and acid-base balanceFrench-language works237,207