MétaCan
Menu
Back to cohort
Record W4412868685 · doi:10.1002/acm2.70159

A novel method to simulate radiographs of 3D printed objects

2025· article· en· W4412868685 on OpenAlexafffund
Maxwell C. Campbell, Steven I. Pollmann, Jaques S. Milner, Emily Lalone, David W. Holdsworth

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2025
Typearticle
Languageen
FieldEngineering
TopicAnatomy and Medical Technology
Canadian institutionsRobarts Clinical TrialsWestern University
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsRadiographyComputer science3d printedComputer graphics (images)Medical physicsOrthodonticsArtificial intelligenceRadiologyMedicineBiomedical engineering

Abstract

fetched live from OpenAlex

BACKGROUND: 3D printing has a number of applications within medicine and healthcare. In applications involving radiography, the internal infill structure and external geometry of a 3D printed part can produce undesirable artifacts, limiting the full potential of 3D printing as a manufacturing technology. While the mechanical performance of a 3D printed part can be easily simulated, it is difficult to simulate the radiographic artifact produced. PURPOSE: The purpose of this work was to develop a tool that allows users to simulate the radiographic artifact produced by a 3D printed object. METHODS: Three regular hexagons of identical geometry were sliced and 3D printed using polylactic acid (PLA) filament on a fused deposition modeling (FDM) 3D printer with varying infill patterns: rectilinear grid, cubic, and gyroid. The hexagons were then radiographed using clinical-standard scanning protocols. The captured radiographs were compared to simulated radiographs generated using the G-Code developed when the objects were sliced. The physical and simulated virtual radiographs were compared to one another, and the simulated angle of least and greatest artifact was noted. RESULTS: Strong visual agreement was found between the physically captured and simulated virtual radiographs. The projection angles that produced the least amount of artifact were 22.5°, 22.5°, and 12.25° for grid, cubic, and gyroid infills, respectively. The projection angles that produced the greatest amount of artifact were 0°, 45°, and 45° for grid, cubic, and gyroid infills, respectively. CONCLUSIONS: This work provides designers of 3D printed components with a new way to evaluate a design's radiographic performance. Previously, designers would have to physically print and radiograph a part to determine the artifact produced. This work outlines the development of a tool that simulates the radiograph of a 3D printed part from multiple different projections, saving designers time to iterate to their final design.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.960
Threshold uncertainty score0.616

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.018
GPT teacher head0.357
Teacher spread0.339 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2025
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAnatomy and Medical TechnologyFrench-language works237,207